Appendix B: Installation troubleshooting
This section provides some simple strategies to help you troubleshoot an installation of a media
server. This section includes:
●
Troubleshooting the installation of the media server hardware
●
Troubleshooting the configuration of the media server hardware
●
Troubleshooting the installation of the license file and the Avaya authentication file
Troubleshooting the installation of the media server
hardware
.
Problem
Possible solution
No power to the
UPS
●
Ensure that the UPS is plugged into the outlet.
●
Ensure that the outlet has power.
●
For other solutions, see the user guide for the UPS.
No power to the
media server
●
Ensure that the circuit pack is seated.
●
Ensure that the media gateway is plugged into the UPS.
●
Ensure that the UPS has power.
The SIPI LEDs
flash
●
Ensure that the SIPI is in the correct slot. Use slot 1 for the G650
Media Gateway, slot 2 for the G600 Media Gateway, and the
Tone-Clock slot for all others.
●
Ping the SIPI from server.
●
Ping the server from the SIPI.