Issue 4 October 2002
163
555-233-116
11
Stratum 3 clock
The Stratum 3 clock is an optional feature for digital frame timing that couples the
clock output to local clocks. This chapter provide information on setting the option
switches on the clock. For installation information refer to the appropriate
installation or upgrade book for your system.
NOTE:
The information in this chapter does not apply to the G700 Media Gateway
configurations. There is no way to physically connect the G700 tone clock
(resident on the motherboard) to an external Stratum 3 clock source.
Set clock options
There are four sets of option switches on the clock. Proceed as follows.
1. Set the options on the clock input board (CI) per
Table 16
.
Table 16.
CI Option Switch Settings
Switch
Function
Position
1
T1 select
OFF = enable (default)
ON = disable
2
CC select
OFF = enable
ON = disable (default)
3
Framing select
OFF = ESF
ON = D4 (default)
4
BX.25
OFF = enable
ON = disable (default)
Summary of Contents for MultiVantage
Page 6: ......
Page 24: ...About this book 555 233 116 24 Issue 4 October 2002...
Page 120: ...DEFINITY LAN gateway system 555 233 116 120 Issue 4 October 2002...
Page 134: ...Terminal server installation 555 233 116 134 Issue 4 October 2002...
Page 162: ...ISDN converters and adapters 555 233 116 162 Issue 4 October 2002...
Page 172: ...Busy tone disconnect equipment for non U S installations 555 233 116 172 Issue 4 October 2002...
Page 178: ...Call detail recording CDR option settings 555 233 116 178 Issue 4 October 2002...
Page 188: ...DEFINITY INADS 555 233 116 188 Issue 4 October 2002...
Page 196: ...Music on hold 555 233 116 196 Issue 4 October 2002...
Page 224: ...Multimedia communications products MMCX MMCH ESM 555 233 116 224 Issue 4 October 2002...
Page 242: ...Connector and Cable Pinout Charts 555 233 116 242 Issue 4 October 2002...