DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN
555-233-121
Issue 2
November 2000
SREPN Installation
1-18
Administer the Release 9r and SRP
1
Administration of the Release 9r
1. Log onto the DEFINITY ECS R9r.
1. Type display system-parameters maintenance and press
Enter
. Record
the product ID for later use.
2. Choose an option and enter one of the following commands:
■
If changing an existing EPN to an SREPN, type change cabinet
<number> (number is the cabinet number of the SREPN) and press
Enter
.
■
If adding a new EPN as an SREPN, type add cabinet <next> (next
gives you the next available number).
3. In the
Survivable Remote EPN?
field, type y.
4. In the
Survivable Remote Processor ID
field, add the product ID of
the SRP. The product ID is located on the display system-parameters
maintenance screen on the SRP system access terminal.
5. Press
Enter
to effect the changes.
Administration of the SRP
First, administer the hardware, then the software, and, finally, any individual
features.
Administering the hardware
1. On the Release 9r system, type list cabinet and press
Enter
. Identify the
port network of the SREPN. See
Figure 1-8
.
Figure 1-8.
List cabinet screen
list cabinet SPE B
CABINET REPORT
No. Type Layout Room Floor Building A B C D E
1 PPN 5-car CS_1 1 ABC_DE PN 01 PN 01 PN 01 SN 01 SN 01
2 EPN 5-car CS_1 1 ABC_DE PN 04 PN 04 PN 04 PN 16 PN 16
3 sEPN 5-car CS_1 1 ABC_DE PN 05 PN 05 PN 05 SN 44 SN 44
4 EPN 5-car B-32 B VWX_YZ PN 06 PN 06 PN 06 SN 07 SN 07
5 EPN 5-car 2-12 2 MNO_PQ PN 08 PN 08 PN 08 SN 09 SN 09
6 EPN 5-car E-51 1 VWX_YZ PN 10 PN 10 PN 10 SN 11 SN 11