2-4
Chapter 2
Cajun P550R/P880/P882 Switch Installation Guide
Preventing
Electrostatic
Discharge
To prevent electrostatic discharge (ESD) from damaging the module
components:
1.
Always wear a grounded electrostatic discharge (ESD) wrist
strap when installing and removing modules from the switch
chassis. Ground the other end of the ESD strap by attaching
to the chassis.
2.
Ground the chassis. The unit is grounded through the power
cord when it is connected between the unit and the primary
power source.
3.
Lay out the static-dissipative work surface (ESD mat) on a flat
surface.
*Note:
Avaya does not supply the required ESD mat.
4.
Connect the ground cord assembly to the ESD mat and to the
ground plug on the switch fan tray.
Installing the
Chassis
The system can be installed by:
■
Rack Mounting the System
■
Installing the System on a Table Top
Rack Mounting the System
To install the switch in a rack:
WARNING
To avoid physical injury, three people are required to safely install
the switch in a rack: two to lift the system into place, and a third to
screw the system to the rack using a Phillips-head screwdriver. A
fully-loaded P550R switch weighs 60 kg (130 lbs). A fully loaded
P882 switch weighs 80 kg (182 lbs).
WARNING
Do not use the handles on the power supplies or fan assembly to lift
the system.