Rack Mounting (Optional)
Issue 2 July 2005
43
2. Ensure that the combination of equipment in the rack will not cause an overload or
overcurrent condition on the power strip being used and/or the customer's branch circuit.
3. A C360 switch weighs a maximum of 15 pounds (6.8 kg). Be careful when installing or
removing the C360 switch from the rack.
4. If a power strip is being used in the rack, ensure that it has a reliable earth connection. If the
C360 equipment will be plugged directly into a wall outlet, ensure that there is a reliable
ground connection at the outlet.
5. Ensure that the internal rack ambient temperature is within the operating specification limits
of the C360.
6. Ventilation for the C360 is from side to side. Ensure that there is adequate space on each
side of the C360 equipment when installed in the rack to allow sufficient airflow.
Place the C360 in the rack as follows:
1. Position the brackets as shown in
Figure 9: C360 Rack Mounting
2. Firmly fix the brackets to the chassis with the screws provided. Use four screws to fix each
bracket to the switch.
3. Position the switch in the rack.
4. Fasten the switch in the rack with the screws provided.
Figure notes:
1. Front mount position
2. Mid-mount position
C363T
In
1
2
Summary of Contents for C360 Manager
Page 17: ...Issue 2 July 2005 17 Section 1 Avaya C360 Overview...
Page 18: ...18 Installation and Configuration Guide Avaya C360 Multilayer Stackable Switches version 4 5...
Page 29: ...Issue 2 July 2005 29 Section 2 Installing the C360...
Page 30: ...30 Installation and Configuration Guide Avaya C360 Multilayer Stackable Switches version 4 5...
Page 91: ...Issue 2 July 2005 91 Section 3 Avaya C360 Configuration...
Page 92: ...92 Installation and Configuration Guide Avaya C360 Multilayer Stackable Switches version 4 5...
Page 211: ...Issue 2 July 2005 211 Section 4 Troubleshooting and Maintaining the Avaya C360...
Page 212: ...212 Installation and Configuration Guide Avaya C360 Multilayer Stackable Switches version 4 5...