Avante International Technology, Inc.
Version
4.4.3
14
When the VOTE-TRAKKER™ confirms that all the critical components are functional, it will
print out a report detailing all the tests performed (see Figure 4.1.3O).
Description of Test Report:
- Election Type: Based on description assigned
during ballot generation.
- Test Time: Time the report was printed.
- Vote-Trakker: The network identification of
the computer in the Vote-Trakker™.
- Software Version: The version of the Voting
module.
- Hardware Version: The version number of
the Vote-Trakker™ hardware.
- Machine ID: Assigned during ballot
generation. A unique number.
- Machine Code: Used for the voter receipt.
- Allocated Name: The name assigned in ballot
generation for this particular Vote-Trakker™.
- Machine Status: Either closed or open for
voting.
- Raw Data File: Checks raw data file(s) for
availability and to make sure they are the same.
- Times are listed for opening, closing, first
and last cast of votes.
- Each major device is checked for operational
status.
- Each storage media is checked for available
memory size. If empty (e.g. no floppy in drive)
the Test will read EMPTY!
- Spaces are provided to write down the
counter information and appropriate signatures.
Spaces are provided for signatures and
countersignatures for all parties to
agree that the machine is ready for
voting.
Election Type:
General Election
Test Time:
2002-3-25 15:01:41
Vote-Trakker:
VTP000010001007
Software Version
4.3
Hardware Version
1.3.0
Machine ID:
2
Machine Code:
02
Allocated Name:
VTP000010001007
Machine Status:
Close
Raw Data File is OK!
03-20-2002 06:45:58
Open Poll by Polling Official 11,22
03-20-2002 06:46:09
First Ballot Cast
03-20-2002 15:24:25
Last Ballot Cast
03-20-2002 16:00:03
Close Poll by Polling Official 11,22
Device Test Status
Battery: PASSED!
100.00%
Counter: PASSED!
Printer: PASSED!
Sensor: PASSED!
Smart Card:
PASSED!
Sound:
PASSED!
Store
Media
Size(Available) Test
A:\Floppy 1344.2K
AVAILABLE
C:\Hard
Drive
16499342.5K
AVAILABLE
D:\CD-ROM
681080
K AVAILABLE
E:\Flash Mem
31202 K AVAILABLE
Beginning Public Counter Number
Ending Public Counter Number
Beginning Protective Counter Number
Ending Protective Counter Number
Polling Officials Signature
X______________________________________________
X______________________________________________
Observers: X___________________________________
Figure 4.1.3O