Warning and information messages on display in English
Text on display in English:
Explanation:
ENGINE OIL PRESSURE LOW
Engine warns user from low oil pressure
AIR FILTER IS CLOGGED
Engine air filter is clogged and needs cleaning
VOLTAGE LOW
Battery voltage is below low battery limit
VOLTAGE HIGH
Battery voltage is higher than normal
COOLANT TEMPERATURE HIGH
Engine coolant is too hot and operator is notified
ENGINE POWER REDUCED TO 80%
Engine coolant is so hot that engine power is reduced to protect from
damage
ENGINE POWER REDUCED TO 40%
Engine coolant is so hot that engine power is reduced significantly to
protect from damage
CHECK ENGINE
Check engine alarm is active also light on display
WATER IN FUEL
Engine has noticed excessive amount of water in fuel, system should be
checked
ENGINE SERVICE NEEDED IN
Operator is informed from upcoming service time
ENGINE MALFUNCTION
Engine has major problem and MIL light is active
Reset successful!
Reset of message or value has been done successfully (for example
service hours)
Password incorrect!
User typed in wrong password
DPF: BEWARE OF HOT EXHAUST
Exhaust is hotter than normally due to DPF regeneration, this is normal
during active regeneration
DPF: FORCED REGENERATION NEEDED
Engine is requesting operator to activate forced regeneration process
DPF: SERVICE NEEDED, STOP
Soot level in DPF is so high that DPF regeneration can be done only with
service tool
NO MESSAGES
No messages active
CAN CONNECTION ERROR ENGINE ECU
CAN (control area network) connection is not working between display
and Engine ECU (Electronic control unit)
CAN CONNECTION ERROR VEHICLE ECU
CAN (control area network) connection is not working between display
and Vehicle ECU (Electronic control unit)
ENGAGE P-BRAKE TO START FORCED REGEN During forced regeneration parking brake must be activated, operator is
notified to engage parking brake when forced regeneration button is
pressed
DPF: POWER INCREASE REQUESTED
During active regeneration (machine is used normally) some extra power
is needed to have regeneration working. Power can be increased by
adding load to hydraulic system (drive, boom or auxiliary hydraulics)
DPF: FORCED REGEN ON, DO NOT DISTURB
DPF is being regenerated and process should not be disturbed. Message
goes away when process is finished
DPF: ENGINEPOWER REDUCED TO 50%
Soot level is over 100% of allowed, only half of the engine power will be
available
Service information
Title for service info page
Total engine hours
Engine hours read from diesel engine
Service due
Time to next service
Next service engine hours
Engine hours when machine should be serviced next time
Service menu
Title for service menu
Parameter setting
Title for parameter settings menu
System information
Title for system information menu
Error information
Title for error information menu
System time
Parameter name for system time
Temperature unit
Parameter name for setting temperature unit (C/F)
Volume unit
Parameter name for setting volume unit (l/gal)