S
M
P
T
HK
S
M
P
T
AUTOMATIC
ROTATION SPEED
CONTROL VALVE
3.
HYDRAULIC SYSTEM WITH CONSTANT DISPLACEMENT PUMP
The demanded oil flow is to be ensured with proper
hydraulic pump choice. In systems with redundant
hydraulic flow an installation with
DYNASET PRIORITY
VALVE
is recommended.
Installation with a standard pressure compensated
3-way valve should be avoided in order to close off
potential waving in hydraulic system.
ALSO AVAILABLE for hydraulic systems with constant
displacement pump:
DYNASET FREE CIRCULATION VALVE with solenoid
and pressure control, type
VKV 90—3/4.
CONNECTION TO THE AIR SUPPLY SYSTEM
It is recommended to install distribution valve to
a pressure line near the compressor in order to
the unit with a blow gun when necessary.
Compressor can be connected to the air supply system (or consumer) with a proper fitting and cut-off valve
(options). The internal diameter of pipe / hose used for compressor’s connection should be at least equal to
AP-port to keep the pressure drop minimal. The length of a pipeline, laid with the pipe of same diameter as
AP-port, can be 50 m as maximum. For longer lines use larger diameter.
Moisture separator to the pressure line is
optional.
8/21
MAY CHANGE WITHOUT PRIOR NOTICE
... INSTALLATION
HYDRAULIC COMPRESSOR HK400/8-23_PNE
July 2013 JLe