Cleaning
Keep the compressor clean to ensure effective cooling and for the best performance of the compressor. A
blowgun is a useful tool to clear dust from all surfaces of compressor. Especially the compressor block,
control valves, safety relief valve, air filter, and cooling fan must be kept clean. Cleaning with water should be
avoided. The compressor must not be washed with a pressure washer. Touch up paint where needed to
prevent rust damage.
7.4.
Oils
Checking oil level
To check the oil level there is a sight glass on the
side of the compressor block. For correct reading,
the level must be checked in upright position after
the compressor has been stopped for long enough
to allow oil to drain back to oil pan.
The oil level must be between the lower edge and
the middle of the sight glass.
Oil type
Viscosity
Operating
temperature
Change
interval,
maximum
Oil volume
Multi-grade
SAE 10W-30
-5ºC … +40ºC
500 h / 12 m *
SAE 10W
-25ºC … +20ºC
500 h / 3 m *
SAE 30
-5ºC … +30ºC
500 h / 3 m *
Diesel engine oil
API CC
MIL-L-2104
MIL-L-46152 B
SAE 40
+5ºC … +40ºC
500 h / 3 m *
0,91 l
*The first oil change must be made after a maximum of 150 operating hours.
7.5.
Removal from service
Follow local laws, guides and recommendations concerning waste disposal and recycling of materials.
Before disposal of the compressor, remove all oil and filters and dispose of them properly. Separate
compressor parts according to their material and give them to proper collecting facilities. Customers can
send used equipment to Avant Tecno Oy for disposal or recycling at their own cost. All sent material must
bear customer contact information.