MASONRY FIREPLACE INSERT INSTALLATION (Cont.)
Installation Using a Direct Connection (Continued)
9.
To install the surround panels, follow the directions listed in the section "INSTALLING SURROUND
PANELS" . NOTE: Surround panels are not required for a direct connection if a block-off plate is
used.
Follow the installation instructions in reverse order for periodic inspection and cleaning.
SIDE VIEW OF FIREPLACE INSERT DIRECT CONNECTION
Non-Combustible
Material
Optional Surround
Panel
Block-off Plate
Remove Damper or
Wire it Open
Stainless Steel
Chimney Connector
Must Extend to Clay
Flue Liner or at least
one foot beyond
Block-off Plate
Insulation
(Optional)
Airtight Insulated
Clean-Out
Clay Flue Liner with
Required Air Space
Block-off Plate
Insulation
18" Min.
996 Extended 45 Flue Shown
Here Ð Follow the clearances
for the 996 Flush Top Flue
when that model is used.
Follow the directions on the previous page for installation.