Page 46
ZERO CLEARANCE (METAL) FIREPLACE INSTALLATION
(Continued)
6.
After the plate has been trimmed, drill four 1/8"
holes in the plate as shown. These holes will be
used for mounting the plate to the inside of the
fireplace.
7.
Place the plate inside the fireplace over the
chimney flue centering the 6-1/4" hole in the
chimney flue exit. Mark the location of the 1/8"
mounting holes on the inside top of the fireplace.
Drill the holes with a 1/8" drill bit.
8.
Put the starter pipe through the block off plate,
leaving enough sticking through to allow it to be
connected to the appliance.
BLOCK-OFF PLATE
14"
14"
6-1/4"
1/8" Holes
9.
You can now place your appliance into the
fireplace opening and position the starter
pipe so it can be easily pushed into the flue
opening on top of the insert.
10. If the stove needs to be leveled, follow the
directions for using the leveling bolts
described in the specifications portion for
zero clearance installation.
11. Once the insert is in position and leveled, connect the 6" liner to the unit and secure it with sheet metal
screws through the holes in the flue collar.
Install Screws in
Flue Collar
12. To install the surround panels or front blower, follow the directions listed in the section "INSERT
OPTIONAL EQUIPMENT". NOTE: Insulation for the surround panels is not required.
Summary of Contents for 996 Extended