91
97.0
1.013
1.100
1.194
4.462
4.505
4.544
911
923
934
98.0
0.9826
1.068
1.160
4.476
4.518
4.557
914
925
936
99.0
0.9535
1.037
1.127
4.489
4.530
4.569
916
928
939
100.0
0.9252
1.007
1.095
4.502
4.543
4.580
919
930
941
101.0
0.8981
0.9778
1.064
4.515
4.555
4.592
922
933
943
102.0
0.8717
0.9497
1.034
4.527
4.566
4.603
924
935
946
103.0
0.8463
0.9225
1.005
4.539
4.578
4.613
927
938
948
104.0
0.8218
0.8963
0.9767
4.551
4.589
4.624
929
940
950
105.0
0.7981
0.8710
0.9497
4.562
4.599
4.634
931
942
952
Temperature sensor R-T analysis table (20K)
Sensor standard resistance
:
20KΩ±3% B:B(25/50)=3950K±2
%
reference temperature
:
25
(
℃
)
MCU_A/D exchange ±3LSB
(
at10bit
)
Series
(
sampling
)
resistor
:
10
(
KΩ
)
±1
%
Single chip (A/D reference voltage) supply voltage
:
5V
Temp
Resistance
(
KΩ
)
MCU Input voltage
(
V
)
A/D Exchange value
(
℃
)
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
-30
318.3
347.0
377.6
0.128
0.140
0.154
23
29
34
-29
299.6
326.2
354.6
0.136
0.149
0.163
25
30
36
-28
282.2
306.9
333.4
0.144
0.158
0.173
27
32
38
-27
265.9
289.0
313.5
0.153
0.167
0.183
28
34
40
-26
250.8
272.2
295.1
0.162
0.177
0.194
30
36
43
-25
236.6
256.5
277.9
0.172
0.188
0.205
32
38
45
-24
223.3
241.9
261.8
0.182
0.198
0.216
34
41
47
-23
210.9
228.2
246.7
0.193
0.210
0.229
37
43
50
-22
199.2
215.3
232.6
0.204
0.222
0.241
39
45
52
-21
188.3
203.3
219.4
0.216
0.234
0.255
41
48
55
Summary of Contents for ASW-H09B5B4/FAR3DI-C3
Page 1: ...AUX Imp Exp Company Limited F Freedom Inverter Split Type Air Conditioner ...
Page 2: ...This manual is for professional maintenance personnel only ...
Page 7: ...4 2 2 Outdoor Unit 1 3P 1 8P 新 2P 2 3P ...
Page 17: ...14 5 Electrical Part 5 1 Wiring Diagram Indoor Unit 09K 12K 18K 24K Outdoor Unit 09K 12K ...
Page 18: ...15 18K 24K ...
Page 19: ...16 Part II Installation and Maintenance 6 Main Tools for Installation and Maintenance ...
Page 71: ...68 Remote Control Can Not Work Trouble shooting procedure ...
Page 72: ...69 9 Exploded Views and Parts List 9 1 Indoor Unit ...
Page 74: ...71 9 2 Outdoor Unit ...
Page 77: ...74 3 Remove air louver 4 Remove air filter 5 Remove Medium frame wiring cover ...
Page 78: ...75 6 Remove medium frame 7 Remove Control the lid 8 Remove Electric box ...
Page 79: ...76 9 Remove press plate 10 Remove component 11 Remove pipe clamp ...
Page 80: ...77 12 Remove evaporator 13 Remove the blade 14 Remove Motor press plate ...
Page 81: ...78 15 Remove Motor 10 2 Outdoor Unit Part Procedure Diagram 1 Outdoor unit ...
Page 82: ...79 2 Remove top cover 3 Remove control box cover ...
Page 83: ...80 4 Remove panel grille 5 Remove front panel ...
Page 84: ...81 6 Remove E part cover 7 Remove right side panel ...
Page 85: ...82 8 Remove axial flow blade 9 Remove outer motor ...
Page 86: ...83 10 Remove electric box assy 11 Remove motor support ...
Page 87: ...84 12 Remove reactor 13 Remove partition board ...
Page 88: ...85 14 Remove left side support plate 15 Remove pipeline assembly ...
Page 89: ...86 16 Remove stop valve assembly 17 Remove valve plate ...