Oblique
。
90
Roughness
Burr
Main cause for refrigerant leakage
is due to defect in the flaring work.
Carry out correct flaring work
using the following procedure:
A: Cut the pipes and the cable.
1. Use the piping kit accessory or pipes
purchased locally.
2. Measure the distance between the indoor
and the outdoor unit.
3. Cut the pipes a little longer than the
measured distance.
4. Cut the cable 1.5m longer than the pipe
length.
1. Flaring work
Pipe
Reamer
Point down
Fig.54
Fig.55
B: Burr removal
1. Completely remove all burrs from the cut
cross section of pipe/tube.
2. Put the end of the copper tube/pipe in a
downward direction as you remove burrs in
order to avoid dropping burrs into the tubing.
Flare nut
Copper tube
Fig.56
C: Putting nut on
Remove flare nuts attached to indoor and
outdoor unit, then put them on pipe/tube
having completed burr removal.(not possible
to put them on after flaring work)
Additional charge
Max. Length for all rooms (m)
OU higher than IU
OU lower than IU
Max. Leng th for one indoor unit (m)
Max. height different between
indoor and outdoor unit (m)
Max. height different between indoor units (m)
Before installing, make sure that the height difference, the length of refrigerant pipe and number of bends
between indoor and outdoor units, meet the following specifications.
Outdoor unit
Indoor unit
UNIT
Max. lenght:
5m
10m
10m
Max. height difference:
Indoor unit
Indoor unit
Note: If the outdoor unit is installed above the indoor units and the sum
of all the tanks is more than 7m, an oil trap must be installed in the
gas pipe every 3 meters.
10
15
40
25
30
15
15
AM2
(2x1)
AM3
(3x1)
15
10
*(1)
*(1)
60
35
15
AM4 / AM5
(4x1 / 5x1)
15
10
*(1)
80
AM2 (2x1)
R32 (g)
UNIT
20 x (Total length - 15)
20 x (Total length - 22,5)
15m
22,5m
20 x (Total length - 30)
30m
20 x (Total length- 37,5)
37,5m
AM3 (3x1)
AM4 (4x1)
AM5 (5x1)
Charged until
Additional
charge
3. Refrigerant pipe connection
46
Summary of Contents for AMW-NFH 14
Page 1: ...Manual de usuario e instalación R32 MULTI INVERTER SERIE AMW NFH CL80200 CL80209 ...
Page 2: ... ES EN 3 38 2 ...
Page 26: ...26 DISPLAY 4 DISPLAY iFEEL 5 iFEEL 6 TIMER ...
Page 30: ...30 3 FUNCIONAMIENTO ...
Page 31: ...31 4 ATENCIÓN 5 CAMBIO DE BATERÍAS ...
Page 65: ...65 3 OPERATION ...
Page 73: ... ...
Page 74: ......
Page 75: ......
Page 76: ...C PROVENZA 392 P2 08025 BARCELONA SPAIN 34 93 446 27 80 ...