REFRIGERANT PIPE CONNECTION
4. Refrigerant pipe connection
Oblique
。
90
Roughness
Burr
Main cause for refrigerant leakage
is due to defect in the flaring work.
Carry out correct flaring work
using the following procedure:
A: Cut the pipes and the cable.
1. Use the piping kit accessory or pipes
purchased locally.
2. Measure the distance between the indoor
and the outdoor unit.
3. Cut the pipes a little longer than the
measured distance.
4. Cut the cable 1.5m longer than the pipe
length.
1. Flaring work
Pipe
Reamer
Point down
Fig.54
Fig.55
B: Burr removal
1. Completely remove all burrs from the cut
cross section of pipe/tube.
2. Put the end of the copper tube/pipe in a
downward direction as you remove burrs in
order to avoid dropping burrs into the tubing.
Flare nut
Copper tube
Fig.56
C: Putting nut on
Remove flare nuts attached to indoor and
outdoor unit, then put them on pipe/tube
having completed burr removal.(not possible
to put them on after flaring work)
Additional charge (R410A)
Max. Length for all rooms (m)
OU higher than IU
OU lower than IU
Max. Length for one indoor unit (m)
Max. height different between
indoor and outdoor unit (m)
Max. height different between indoor units (m)
Before installing, make sure that the height difference, the length of refrigerant pipe and number of bends
between indoor and outdoor units, meet the following specifications.
Outdoor unit
Indoor unit
Charged until
Total Liquid Length 1/4":
22 x (Total length - 15)
(Total Liquid Length 1/4")
Additional
charge
UNIT
AM2
(2 to 1)
AM3
(3 to 1)
Max. lenght:
5m
10m
10m
Max. height difference:
Indoor unit
Indoor unit
Note: If the outdoor unit is installed above the indoor units and the sum
of all the tanks is more than 7m, an oil trap must be installed in the
gas pipe every 3 meters.
AM2 (2 to 1)
(g)
UNIT
10m
15m
AM3 (3 to 1)
(Total Liquid Length 1/4")
Total Liquid Length 1/4":
22 x (Total length - 10)
38
10
15
40
20
20
15
15
15
10
*(1)
60
Summary of Contents for AM Series
Page 1: ...Manual de usuario e instalación MULTI INVERTER SERIE AM CL80100 CL80112 ...
Page 2: ... ES EN 3 32 2 ...
Page 27: ...CONTROL REMOTO 27 ...
Page 28: ...CONTROL REMOTO Este botón no tiene función en este equipo 28 ...
Page 29: ...CONTROL REMOTO 29 ...
Page 30: ...CONTROL REMOTO 30 ...
Page 31: ...CONTROL REMOTO 31 ...
Page 56: ...REMOTE CONTROLLER 56 ...
Page 57: ...REMOTE CONTROLLER This button has no function 57 ...
Page 58: ...REMOTE CONTROLLER 58 ...
Page 59: ...REMOTE CONTROLLER 59 ...
Page 61: ...61 ...
Page 62: ...C PROVENZA 392 P2 08025 BARCELONA SPAIN 34 93 446 27 80 ...