INDOOR AND OUTDOOR UNIT INSTALLATION
1. For the left-hand and right-hand piping,
remove the pipe cover from the side
panel.
2. For the rear-right-hand and rear-left-hand
piping, install the piping as shown in Fig.10.
3. Fix the end of the connective pipe. (Refer
to Tightening Connection in REFRIGERANT
PIPING CONNECTION)
Right-hand piping
Left-hand piping
Rear-right piping
Rear-left piping
Fig.9
Fig.10
Bundle the tubing, connecting cable, and drain
hose with tape securely, evenly as shown in
Fig.11.
Because the condensed water from rear of the
indoor unit is gathered in ponding box and is
piped out of room. Do not put anything else in
the box.
Indoor unit
Connective
pipe
Pipe room
Ponding box
Wrapping belt
Connective
cable
Drain hose
.
.
.
. .
.
.
.
.
.
.
.
.
.
.
.
.
...
..
.
.
.
.
.
.
.
. .
.
Fig.11
Connect the indoor unit first, then the
outdoor unit.
Do not allow the piping to let out from
the back of the indoor unit.
Be careful not to let the drain hose slack.
Heat insulated both of the auxiliary piping.
Be sure that the drain hose is located at
the lowest side of the bundle. Locating
at the upper side can cause drain pan
to overflow inside the unit.
Never intercross nor intertwist the power
wire with any other wiring.
Run the drain hose sloped downward to
drain out the condensed water smoothly.
Connective pipe installation
Piping and w
rapping
Caution
3. Outdoor unit installation
Install the outdoor unit on a rigid base to prevent increasing noise level and vibration.
Determine the air outlet direction where the discharged air is not blocked. In the case that
the installation place is exposed to strong wind such as a seaside, make sure the fan operating
properly by putting the unit lengthwise along the wall or using a dust or shield plates.
Specially in windy area, install the unit to prevent the admission of wind. If need suspending
installation, the installation bracket should accord with technique requirement in the
installation bracket diagram.
The installation wall should be solid brick, concrete or the same intensity construction, or
actions to reinforce, damping supporting should be taken. The connection between bracket and
wall, bracket and the air conditioner should be firm, stable and reliable.
Be sure there is no obstacle which block radiating air.
36
Summary of Contents for AM Series
Page 1: ...Manual de usuario e instalación MULTI INVERTER SERIE AM CL80100 CL80112 ...
Page 2: ... ES EN 3 32 2 ...
Page 27: ...CONTROL REMOTO 27 ...
Page 28: ...CONTROL REMOTO Este botón no tiene función en este equipo 28 ...
Page 29: ...CONTROL REMOTO 29 ...
Page 30: ...CONTROL REMOTO 30 ...
Page 31: ...CONTROL REMOTO 31 ...
Page 56: ...REMOTE CONTROLLER 56 ...
Page 57: ...REMOTE CONTROLLER This button has no function 57 ...
Page 58: ...REMOTE CONTROLLER 58 ...
Page 59: ...REMOTE CONTROLLER 59 ...
Page 61: ...61 ...
Page 62: ...C PROVENZA 392 P2 08025 BARCELONA SPAIN 34 93 446 27 80 ...