Page 3
Excessively high chlorine levels can cause corrosion damage to pool fixtures and
equipment.
For maximum cell life, maintain water in a balanced condition. Water maintained in a
scaling condition will shorten cell life and may render the Digital Nano/Nano+
inoperative. Damage and/or service calls, caused by improper water balance, will NOT
be covered under the equipment warranty.
Scraping or scratching the titanium blade’s edge or surface will damage the blade
catalyst coating and cause premature failure of the cell... warranty will be voided. Never
use any sharp or metallic objects to remove scale.
Reduced polarity reversing cycle times will reduce cell life, and should only be used due
to uncontrollable scale formation on the cell. ALWAYS test and adjust water balance,
before attempting scale control via shortening reverse period.
The Tri-sensor should not be pulled out at an angle, or the flow paddle or flow post may
be damaged.
SAVE THESE INSTRUCTIONS