Page 18
SECTION 7 - PROGRAMMING
7.1 CONTROL PANEL
7.1.1
Button Overview
7.1.2
MENU Button
The MENU button is used to leave the normal operation mode and enter the program and
diagnostic modes. Use the UP/DOWN arrows and SELECT button to navigate through the
menus and sub-menus. Note: to permit quick access to features, some functions are accessed
or programmed in several menus.
Test Pool Pilot - displays various operating parameters and diagnostic results.
View Setup - displays the programmed setup parameters.
Owner Options - programs the primary operating parameters an owner would need to
change.
Maintenance Menu - tests and programs the primary features a service technician would
need to access when servicing the system.
Installer Menu - program the initial system setup.
SELECT Button
The SELECT button chooses the displayed menu option. For the
“
Installer Menu
”, press
and hold the SELECT button for approximately 13 seconds to access this feature. The
SELECT button also temporarily disables the buzzer during an error display.
7.1.3
Display Overview
The first line of the display typically indicates Purifier/Chlorine Output Level in percent, or
whether the system is in Boost or Super-Boost mode.
The second line will show the following information:
If Temperature Display is turned on, the temperature in either
°F
or
°C
will be shown.
“
On
” in the lower right corner will indicate whether the cell is generating chlorine.
“
Cover closed
” when the unit detects that the pool cover is closed (purifier/chlorine
output will automatically be reduced) on models that have this feature.
A small dot
after “
On
” in bottom right corner indicates the self-cleaning reverse cycle.
Push
UP
or
DOWN
arrow to
do the following:
Sets Chlorine Level %
Scrolls through Menus
and Sub-Menus
Increases or Decreases
programming values for
menus
CHECK SYSTEM LIGHT
:
Red LED flashes to warn
attention is required
A warning message will
also be displayed
If enabled, an audio alarm
may also be heard when
the system light is flashing
Push
BOOST
:
Select to start 24 hour Boost
mode
Select and hold for eight (8)
seconds to start 72 hour Boost
mode
Select again to cancel Boost
mode
Push
MENU
:
Leave normal operation and
access menus for programming
and diagnostics
Push
SELECT:
Chooses item currently
displayed