Page 8
SECTION 4 - SPECIFICATION AND APPROVALS
4.1 SPECIFICATIONS
SPECIFICATION
75041A,
75041-XX
(
when converted
to 110V-120V in
the field
)
75041A,
75041A-XX
75043A,
75043A-XX
(
when converted
to 110V-120V in
the field
)
75043A,
75043A-XX
Input Power:
110-120 Vac
2.0 A
220-240 Vac
1.0 A
110-120 Vac
2.0 A
220-240 Vac
1.0 A
Cell Maximum Chlorine Output:
PPC1
0.8 lb. /day (15.1 g/hr.) (standard)
0.8 lb. /day (15.1 g/hr.) (optional)
PPC2
not applicable
1.06 lb. /day (20.0 g/hr.) (standard)
Manifold Type
PPM1 or PPM1M
PPM2 or PPM2M
Standard Cell
PPC1
PPC2
Manifold Flow rates:
PPMxx (standard)
Minimum 15 gpm (57 L/min); Maximum 70 gpm (265 L/min)
CoPilot
®
Ozone (optional)
Minimum 25 gpm (95 L/min); Maximum 70 gpm (265 L/min)
Maximum Manifold
Pressure:
75 psi (517 kPa)
Cover Switch Compatible
Digital Nano/Nano+
models:
75041A & 75043A (Discontinued models 75040A & 75042A)
Table 2