6 Vision Sensor Program [Vision Master]
86
© Copyright Reserved Autonics Co., Ltd.
When inspecting inspection items including alignment, alignment is prior to any other inspection
items, so that rotating inspection target by alignment also rotates position of other inspection
items.
If you want to apply alignment to each inspection, check ‘Apply alignment’ in the right bottom.
X: moving X axis coordinate / Y: moving Y axis coordinate / R: angle
Examples of pass/fail when inspecting multiple work including alignment
Registering template of the inspection target (registering alignment)
Applying alignment
Unapplying alignment