6 Vision Sensor Program [Vision Master]
© Copyright Reserved Autonics Co., Ltd.
67
6.6.3.1
Input mode
Input
Signal
Function
0
IN0
Work group change
Bit 0
Work group change
- Clock
Alarm cleared
1
IN1
Work group change
Bit 1
Work group change
- Data
2
IN2
Work group change
Bit 2
Encoder - Up counter
- Quadrature A
3
IN3
Work group change
Bit 3
Encoder - Down counter
- Quadrature B
(1)
Work group change – parallel input (IN0 to IN3)
According to the parallel input, work group is changed.
With parallel input, work group from 1 to 16 can be changed to.
(Following table is based on the High active level.)
Input
Work group
Bit 3 (IN3)
Bit 2(IN2)
Bit 1(IN1)
Bit 0(IN0)
Work group 1
Low
Low
Low
Low
Work group 2
Low
Low
Low
High
Work group 3
Low
Low
High
Low
Work group 4
Low
Low
High
High
Work group 5
Low
High
Low
Low
Work group 6
Low
High
Low
High
Work group 7
Low
High
High
Low
Work group 8
Low
High
High
High
…
…
…
…
…
Work group 16
High
High
High
High