6 Vision Sensor Program [Vision Master]
© Copyright Reserved Autonics Co., Ltd.
73
(3)
Pulse type
You can select pulse type for output.
You can select pulse type only when the output mode is set to ‘Inspection complete’,
‘Inspection result’, or ‘Alarm’.
Pulse: Output signal is output during set output duration.
Latch: Output signal is kept outputting before next output signal.
(4)
Duration
Duration is the time period of maintaining inspection result output signal for.
You can set duration by setting output mode to “Inspection result” and pulse type to “Pulse”.
Setting range is from 1 to 60,000ms.
Timing diagram of output duration (ms).
(5)
Delay type
Delay type is the moment of applying output delay time to. You can set whether to delay
output after inspection completed or to delay output after trigger input.
Delay output after inspection completed
Delay output after trigger input