6 Vision Sensor Program [Vision Master]
© Copyright Reserved Autonics Co., Ltd.
77
(2)
Output inspection result selection
Set output mode in output menu to “inspection result” and set outputting condition among
followings.
Disable
All pass: When all of inspection results are passed, the vision sensor outputs output
signal.
One or more failure: When one or more inspection result is failed to pass, the vision
sensor outputs output signal.
Alignment: When inspection items with alignment are passed, the vision sensor outputs
output signal.
Logic combination: You can set output conditions by setting each logic combination to
pass or fail with logical operator.