Autonics SFC Series Manual Download Page 3

-|Transparent Guide|-

Setting Switches

  

■ Setting Switch for off-delay time

• 

Only off-delay output model

• 

Available to set off-delay time (max. 3 / 300 / 30 sec., depends on model) 

• 

The settings of the switch on the front and back of the product must be the same. 
Other settings are displayed as an error.

• 

If the off-delay time is set as 0 (factory default), the product operates as the 
instantaneous output.

Model

Max. 3 sec.

Max. 300 sec.

Max. 30 sec.

SFC-A322-23-□

SFC-N322-23-□

 

SFC-R212-R23-□

SFC-A322-2300-□

SFC-N322-2300-□

SFC-R212-R230-□

Total 16 

level

0/0.2/0.3/0.4/0.5/0.6/0.

7/0.8/0.9/1.0/1.2/1.4/1.

8/2.0/2.5/3.0 sec.

0/10/20/30/40/50/60/7

0/80/90/100/120/150/

 

180/240/300 sec.

0/1/2/4/5/6/7/8/9/10/

 

12/14/16/20/25/30 sec.

  

■ Setting switch for function 

• 

Only advanced / Non-contact door switch unit.

• 

The setting of switches for each function must meet each other. Other settings are 
displayed as an error 

Function

SW1

SW2

Logic (AND) 

input

Logic (AND) input

OFF

OFF

Not available

ON

ON

Available

Function

SW3

SW4

Instantaneous 

safety output

Off-delay safety 

output

Off-delay safety 

output points

OFF

OFF

S14, S24, S34

S44, S54

ON

ON

S14

S24, S34, S44, S54

Parts Descriptions

Front

01

02

03

04

Back

06

04

05

06

01. Indicators 
02.  Power supply, I/O signal terminals
03.  Safety output (P ch FET or relay) 

terminals

04.  Setting switch for off-delay time

 

(only off-delay output model)

 

The settings of the switch on the front and 
back of the product must be the same. Other 
settings are displayed as an error.

05.  Setting switch for function 

 

(only advanced / non-contact door switch 
unit)

 

The setting of switches for each function 
must meet each other. Other settings are 
displayed as an error.

 

06. Rail Lock

07

08

Expansion 

relay unit

07.  Loop connector 

 

(only advanced / non-contact door switch 
unit)

 

Do not disconnect the loop connector 
when using a single unit. When connecting 
the expansion relay unit, insert the loop 
connector to the loop port of a unit, which 
located at the end position (farthest to the 
right). If the loop connector is not inserted, 
FB error occurs.

08.  Expansion connector

 

When connecting the expansion relay unit, 
remove the loop connector on the top of 
the controller and insert the expansion 
connector.

Indicators

Indicators                      Model

SFC

SFC-A

SFC-N

SFC-ER

SFC-R□12

-□

SFC-R212

-R2□-□

PWR (green) Power

M1 (white)

Safety input 1 ●

M2 (white)

Safety input 2 ●

NS (white)

Non-contact 

door switch 

input

AND (white) Logic input

ERR (red)

Error

FB (white)

Feedback 

start input

OUT1 

(green)

Instantaneous 

safety output ●

OUT2 

(green)

Off-delay 

safety output ㅡ

Installation

  

■ Mounting with bolts

1.  Pull each rail locks to up and down. 

 

(attach/detach: ≥ 25N)

2.  Insert bolts and fix it on rail lock. 

 

(fixing torque: 1.0 N m to 1.5 N m)

  

■ Mounting on DIN Rail

1. Hang the top rail lock to DIN rail.
2. Push and press the module to down direction.
3.  Install END PLATE at both ends of the module to fix the products. 

 

(It is the same way when using one unit.)

  

■ Removing on DIN Rail

1. Insert a screwdriver into the rail hook of the lower rail lock.
2. Lift the screwdriver and pull the lower rail lock downward.
3. Lift the module with the lower rail lock pulled down.

  

■ How to connect the expansion relay units (SFC-ER412-□)

In case of advanced unit and non-contact door switch unit, it is possible to increase the 
number of safety outputs of relay type by connecting expansion relay unit (SFC-ER412- 
□). (Up to 5 expansion relay units can be connected to each controller)
When the safety output of the controller is on, the output of the expansion relay unit 
also goes to on. 
The controller is installed from the end of the left or right side. 
Power of expansion relay unit should be supplied individually. 
E.g.) Installation from the end of left side
1.  Install the expansion relay units (max. 5 units) toward the right side based on the 

controller.

2. Remove the loop connector on the top of the controller.

3.  Connect the expansion connector of each right (expansion relay unit) to the 

expansion connector of the left unit.

4.  Insert the loop connector removed in 2 into the loop port of the unit, which located at 

the end position (farthest to the right).

SFC-A

SFC-N

SFC-ER

Loop connector

1

2

3

4

5

Dimensions

• 

Unit: mm, For the detailed drawings, follow the Autonics web site.

• 

The below is based on SFC-A (screw type) model 

Mounting on 

DIN rail

Panel cut-out

A

B

C

Mounting 

with bolts

2-M4

134

Model

A

B

C

Basic unit

SFC-422-□

22.5

18.3

Screw type: 15.3

Screwless type: 15.5

Advanced unit

SFC-A322-□-□

35

18.3

Non-contact door 

switch unit

SFC-N322-□-□

35

18.3

Expansion relay unit SFC-ER412-□

22.5

18.3

Relay unit

SFC-R412-□

22.5

18.3

SFC-R212-□

17.5

13.3

SFC-R212-R□-□ 22.5

18.3

Summary of Contents for SFC Series

Page 1: ...th the machine control system it may cause malfunction or result in accidents 04 When the connected devices e g motor is not operating after installation check that functions and settings of the product correctly operate as you intended Failure to follow this instruction may result in personal injury economic loss or fire 05 Be sure to consider the delay of the safety output when determining the s...

Page 2: ... voltage Power consumption 01 2 5 W 3 0 W 3 5 W Input ON 11 VDCᜡ 5 mA OFF 5 VDCᜡ 1 mA Input time 50 ms feedback start manual 100 ms Cable 100 m 100Ω 10nF Safety output P channel FET 02 Instantaneous 4 3 03 3 03 Off delay 04 2 03 2 03 Time accuracy 5 5 Load current Below 2 point output DC 1 A Over 3 point output DC 0 8 A Leakage current 0 1 mA Operating time OFF ON 05 Safety input 50 ms Logic input...

Page 3: ...tors Model SFC SFC A SFC N SFC ER SFC R 12 SFC R212 R2 PWR green Power M1 white Safety input 1 ㅡ M2 white Safety input 2 ㅡ NS white Non contact door switch input ㅡ ㅡ ㅡ ㅡ ㅡ AND white Logic input ㅡ ㅡ ㅡ ㅡ ERR red Error FB white Feedback start input ㅡ OUT1 green Instantaneous safety output OUT2 green Off delay safety output ㅡ ㅡ ㅡ Installation Mounting with bolts 1 Pull each rail locks to up and down a...

Page 4: ...F state The duration that the start switch is in the ON state min 100 ms Feedback loop Start switch 24 VDCᜡ M61 M62 Logic input Connect the safety outputs of the upper unit to the logic AND input of the lower unit To use the logic input function SW1 and SW2 of switch for setting function must be set to ON state Up to four units advanced non contact door switch unit can be connected as logic AND co...

Page 5: ...tting value of the switch for off delay time Flash Error at internal circuit and output relay of the expansion relay unit Please contact the Autonics OFF M1 M2 flashes The different input signal between safety input 1 and safety input 2 Check the wiring to the safety input devices Check the input sequence of safety inputs CheckandMaintenance Check installation conditions Checklist Check 1 The dist...

Page 6: ...9 e 4 218 18 year 99 00 SFC A322 23 L SFC A322 2300 4 99 00 SFC A322 2300 L SFC N SFC N322 23 SIL 3 7 36E 09 e 4 183 67 year 99 00 SFC N322 23 L SFC N322 2300 4 99 00 SFC N322 2300 L SFC R SFC R212 SIL 3 5 29E 09 e 4 247 78 year 99 00 SFC R212 L SFC R412 4 99 00 SFC R412 L SFC R212 R23 4 99 00 SFC R212 R23 L SFC R212 R230 4 99 00 SFC R212 R230 L FailureRate ...

Page 7: ...1 Safety Input 2 Feedback Start Input Auxiliary Output Logic Input Safety Output SW1 Safety light curtain MC1 to MC4 Contactor M1 M2 3 phase motor Motor Controller Control Signal Motor Controller Operation timing chart MC3 MC4 a contact MC3 MC4 b contact MC1 MC2 a contact MC1 MC2 b contact Safety light curtain SW1 Motor controller control signal Rotation of M2 motor Off delay time For more informa...

Page 8: ...ntroller Advanced unit Power Expansion Output Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Logic Input Safety Output PLC etc Motor controller Motor Controller Control Signal Expansion Output Expansion Input Power Auxiliary Output Safety Relay Output Safety controller Expansion relay unit PLC etc SW1 Lock release switch SW2 Safety door lock switch SW3 Safety limit switch SW4 ...

Page 9: ... Input Safety controller Non contact door switch unit PLC etc Motor Controller Actuator SFN Series Safety Non Contact Door Switch White Black Brown Blue Motor Controller Control Signal SW1 Lock release switch SW2 Safety door lock switch SW3 Safety limit switch SW4 Safety emergency stop switch SW5 Safety non contact door switch MC1toMC2 Contactor M1 Motor Operation timing chart M1 Rotation of motor...

Page 10: ...Start Input Auxiliary Output Logic Input Safety Output Expansion Output Non Contact Door Switch Input Safety controller Non contact door switch unit PLC etc Actuator SFN Series Safety Non Contact Door Switch White Black Brown Blue Motor Controller Control Signal PLC etc Operation timing chart Safety controller Basic unit Safety controller Non contact door switch unit Start switch SW2 Safety emerge...

Page 11: ... Safety controller Relay unit Feedback Start Input Auxiliary Output Safety Relay Output Power Safety Input 1 Safety Input 2 PLC etc SW1 Safety emergency stop switch SW2 Start switch MC1 MC2 Contactor M1 3 phase motor Operation timing chart M1 Rotation of motor MC1 MC2 a contact MC1 MC2 b contact Safety emergency stop switch SW1 Start switch SW2 When you do not use the logic input M61 M62 set the s...

Page 12: ...mitter SFL A Series Receiver OSSD1 OSSD2 NC NC 24V GND MC1 MC2 MC3 MC4 MC3 MC4 M2 MC3 MC4 MC1 to MC4 Magnetic contactor M1 M2 3 phase motor Safety controller Relay unit PLC etc Power Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Safety Relay Output Operation timing chart MC1 to MC4 b contact MC1 to MC4 a contact Safety light curtain For more information on wiring and detailed...

Page 13: ...1 SW1 Unlock signal SW4 SW2 MC2 MC1 SW3 MC1 MC2 M1 MC1 MC2 GND GND 24V PLC etc SW1 Safety limit switch SW2 Safety door lock switch SW3 Feedback start switch SW4 Unlock switch MC1 to MC4 Magnetic contactor M1 M2 3 phase motor Safety controller Relay unit Off Delay Power Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Safety Relay Output Instantaneous Operation timing chart Off d...

Reviews: