-|Transparent Guide|-

᜸ Caution

  

Failure to follow instructions may result in injury or product damage.

01.  Use the product within the rated specifications.

Failure to follow this instruction may result in fire or product damage.

02.  Use a dry cloth to clean the unit, and do not use water or organic solvent.

Failure to follow this instruction may result in fire.

03.  When connecting the power input and relay output, use AWG 18 (0.8mm

2

) cable 

or over and tighten the terminal screw model with a tightening torque of 0.3 N m. 

Use the copper-conductor wire with the temperature class 60℃.

Failure to follow this instruction may result in fire or malfunction due to contact failure.

04.  Keep the product away from metal chip, dust, and wire residue which might flow 

into the unit.

Failure to follow this instruction may result in fire, product damage or malfunction.

05.  The durability of relay output depends on conditions of relay switching and load. 

Be sure to test under actual operating conditions and use it within the appropriate 

switching cycles without problem on product performance.

Failure to follow this instruction may result in fire or product damage.

06.  Do not touch the relay output terminal immediately after the power source to the 

load is disconnected.

Failure to follow this instruction may result in electric shock.

Cautions during Use

• 

Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.

• 

The power input is insulated and limited voltage/current or use SELV, Class 2 power supply.

• 

Connect a protective device (fuse etc.) to the safety output terminal for short-circuit, 

overcurrent and ground fault protection.

 

Failure to follow this instruction may result in fire or malfunction.

• 

Do not use AC and DC circuits together between safety output terminals. 

 

-SFC-R212: between 13-14 terminal and 23-24 terminal

 

-SFC-R412, SFC-ER412: between 13-14 terminal and 23-24 terminal or between 33-34 terminal 

and 43-44 terminal

 

-SFC-R212-R2□: between 13-14 terminal and 23-24 terminal or between 37-38 terminal and 

47-48 terminal

• 

Keep away from high voltage lines or power lines to prevent inductive noise. In case installing 

power line and input signal line closely, use line filter or varistor at power line and shielded 

wire at input signal line. Do not use the product near the equipment which generates strong 

magnetic force or high frequency noise.

• 

Do not drop the product or expose it to excessive vibration or shock. It may cause failure or 

malfunction.

• 

Be sure to turn off the power before connecting, inspecting and repairing the product. It may 

cause malfunction or short circuit

• 

When mounting the products close to each other, the rated current of the relay output is 3A. 

Do not apply a current greater than 3A. If the current in the relay output flows 3A, or more, 

make sure that the distance between the products should be 20mm or more.

• 

Assessment of conformity to the required safety level is evaluated for the entire system. 

Please consult with a certified certification body regarding the assessment procedure.

• 

Be sure to set the off-delay time to maintain the safety function of the system. Set the setting 

of off-delay switch on both the front and back sides to the same value. If you set it differently, 

an error occurs.

• 

For switches used for safety inputs, logic input and feedback start input, use a switch with 

contacts capable of normally switching the micro loads (24 VDCᜡ, 5mA).

• 

It should be done away regarded as an industrial waste. For more information, please refer to 

laws, regulations and standards in the country or region.

• 

This unit may be used in the following environments.

 

- Indoors (in the environment condition rated in ‘Specifications’)

 

- Altitude max. 2,000m

 

- Pollution degree 3

 

- Installation category Ⅲ

Ordering Information

This is only for reference.
For selecting the specific model, follow the Autonics web site.

SFC

- ❶ ❷ ❸

2

- ❹ ❺ ❻ - ❼

❶ Function

No mark: Basic unit
A: Advanced unit
N:  Non-contact door switch unit

 

(for Autonics SFN Series)

ER: Expansion relay unit
R: Relay unit

❺ No. of Off-delay outputs

No mark: None
2: 2

❷ No. of safety instantaneous outputs

Number: Number of outputs

❻ Max. Off-delay time

Number: Time (unit: sec)

❸ No. of auxiliary outputs

Number: Number of outputs

❼ Terminal type

No mark: Screw
L: Screwless

❹ Off-delay output elements

No mark: P channel FET
R: Relay (Relay unit) 

Unit

Basic

Advanced

Non-contact door switch 

Model

SFC-422-□

SFC-A322-2□-□

SFC-N322-2□-□

Power supply

24 VDCᜡ

Allowable voltage range

85 to 110% of rated voltage

Power consumption 

 01)

≤ 2.5 W

≤ 3.0 W

≤ 3.5 W

Input

ON: ≥ 11 VDCᜡ ≥ 5 mA, OFF: ≤ 5 VDCᜡ ≤ 1 mA

Input time

≥ 50 ms, feedback start (manual) : ≥ 100 ms

Cable

≤ 100 m (≤ 100Ω, ≤ 10nF)

Safety output

P channel FET 

 02)

Instantaneous

4 ×

3 × 

 03)

3 × 

03)

Off-delay 

 04)

-

2 × 

03)

 

2 × 

03)

 

Time accuracy

-

≤ ± 5%

≤ ± 5%

Load current

Below 2-point output: ≤ DC 1 A, Over 3-point output: ≤ DC 0.8 A

Leakage current

≤ 0.1 mA

Operating time

(OFF → ON) 

 05)

Safety input: ≤ 50 ms

-

Logic input: ≤ 200 ms

-

-

Non-contact door switch 

input: ≤ 100 ms

Response (return) time 

 

(ON → OFF) 

05)

 

≤ 15 ms, non-contact door switch input or logic input: ≤ 20 ms

Auxiliary output

2 × PNP transistor: X1, X2 (error)

Load current

≤ 100 mA 

Leakage current

≤ 0.1 mA

Logical AND connections

No. of connections: max. 4 units, no. of total connections: max. 20 units

No. of layers: max. 5 layers, cable length: ≤ 100 m

SFN connections 

 06)

-

-

Max. 30 units

Approval

IEC/EN 61508 (SIL3), IEC/EN 62061 (SILCL3)

IEC/EN 60947-5-1, EN ISO 13849-1 (Category 4, PLe)

UL listed E249635

Certification

ᜢ ᜩ ᜦ

 ᜪ

Unit weight (package)

≈ 70 g (≈ 120 g)

≈ 90 g (≈ 140 g)

≈ 100 g (≈ 150 g)

 01)   Not include the power consumption of loads.

 

(SFC-N exclude the power supplied to the non-contact door switch.)

 02)   Includes a diagnostic pulse (max. 600 ㎲). Be cautious when using the output 

signal as an input signal for the control device.

 03)  Available changing via setting switch on the back side of the product.
 04)  Available to set Off-delay time (max. 3 sec. / 300 sec., depends on model) 
 05)   The operation (response) time of each model. The time increases when a logical connection or expansion relay 

unit is connected. 

 06)  SFC-N units can only be connected to Autonics non-contact door switch units SFN Series.

Specifications

Unit

Expansion relay

Relay

Model

SFC-ER412-□

SFC-R412-□

SFC-R212-□

SFC-R212-R2□-□

Power supply

24 VDCᜡ

Allowable voltage range

85 to 110% of rated voltage

Power consumption 

 01)

≤ 2.5 W

≤ 4.0 W

≤ 4.0 W

≤ 6.0 W

Input

ON: ≥ 11 VDCᜡ ≥ 5 mA, OFF: ≤ 5 VDCᜡ ≤ 1 mA

Input time

≥ 50 ms, feedback start (manual) : ≥ 100 ms

Cable

≤ 100 m (≤ 100Ω, ≤ 10nF)

Safety output

Relay (A contact)

Relay (A contact)

Instantaneous

4 × 

4 × 

2 × 

2 × 

Off-delay 

 02)

-

-

2 × 

Time accuracy

-

-

≤ ± 5%

Capacity

240 VACᜠ 5 A resistance load, 30 VDCᜡ 5 A resistance load

Life expectancy

Mechanical: ≥ 10,000,000 operations, 

 

Malfunction: ≥ 50,000 operations

Contact resistance

≤ 100 mΩ

Inductive load switching

IEC60947-5-1: AC-15(230 V/2 A), DC-13(24 V/1.5 A), UL508: B300/R300

Conditional short-circuit 

current

100 A 

 03)

Operating time (OFF → ON) 

 04)

≤ 30 ms 

 05)

≤ 100 ms

Response (return) time (ON 

→ OFF) 

04)

 

 ≤ 10 ms 

 ≤ 15 ms 

Auxiliary output

1 × PNP transistor: 

X2 (error)

1 × PNP transistor: X1

Load current

≤ 100 mA

≤ 100 mA

Leakage current

≤ 0.1 mA

Expansion units connections

Max. 5 units

-

Approval

IEC/EN 61508 (SIL3), IEC/EN 62061 (SILCL3)

IEC/EN 60947-5-1, EN ISO 13849-1 (Category 4, PLe)

UL listed E249635

Certification

ᜢ ᜦ

ᜢ ᜩ ᜦ

 ᜪ

Unit weight (package)

≈ 100 g (≈ 150 g) 

≈ 110 g (≈ 160 g)

≈ 80 g (≈ 130 g)

≈ 110 g (≈ 150 g)

 01)  Not include the power consumption of loads.
 02)  Available to set Off-delay time (max. 3 sec. / 30 sec., depends on model) 
 03)  Use 6 A fast-blow fuse under the IEC 60127 standard as a short-circuit protection device.
 04)   The operation (response) time of each model. The time increases when a logical connection or expansion relay 

unit is connected. 

 05)  Except operation time of advanced unit, non-contact door switch unit

Pollution

3

Overvoltage category

III

Impulse withstand 

voltag for relay unit

(IEC/EN 60947-5-1)

Input terminals and relay output terminals: 6 kV

Relay contacts between 13-14 / 23-24 and 33-34 / 43-44 (37-38 / 47-48): 6 kV

between 13-14 and 23-24: 4 kV

between 33-34 and 43-44 (37-38 and 47-48): 4 kV

Dielectric strength

Basic / Advanced / Non-contact door switch unit: 

500 VACᜠ 50/60 Hz for 1 min. (between all terminals and case)

Expansion relay / relay unit: 

1,500 VACᜠ 50/60 Hz for 1 min. (between all terminals and case)

2,500VACᜠ 50/60Hz for 1 min. (between input terminals and output 

terminals 

 01)

)

Insulation resistance

≥ 100 MΩ (500 VDCᜡ megger)

Vibration 

 02)

0.75 mm amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, Z 

direction for 1 hour

Vibration (malfunc.) 

02)

0.5 mm amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, Z 

direction for 10 minutes

Shock 

02)

300 m/s

2

 (≈ 30 G) in each X, Y, Z direction for 3 times

Shock (malfunc.) 

02)

100 m/s

2

 (≈ 10 G) in each X, Y, Z direction for 3 times

Protection structure

IP20

Ambient temperature

-10 to 55 ℃, storage: -25 to 65 ℃ (rated at no freezing or condensation)

Ambient humidity

25 to 85 %RH, storage: 25 to 85 %RH (rated at no freezing or condensation)

 01)  In case of relay unit, output terminals between 13-14, 23-24 and 33-34, 43-44 (37-38, 47-48) 
 02)  This data based on the product is mounted with bolts. When installing DIN rail, use the product in an 

environment with small vibration (condition: less than 0.4 mm double amplitude)

P-CH FET 

safety output 

≈ 50 ms

Max. 600 ㎲

Summary of Contents for SFC Series

Page 1: ...th the machine control system it may cause malfunction or result in accidents 04 When the connected devices e g motor is not operating after installation check that functions and settings of the product correctly operate as you intended Failure to follow this instruction may result in personal injury economic loss or fire 05 Be sure to consider the delay of the safety output when determining the s...

Page 2: ... voltage Power consumption 01 2 5 W 3 0 W 3 5 W Input ON 11 VDCᜡ 5 mA OFF 5 VDCᜡ 1 mA Input time 50 ms feedback start manual 100 ms Cable 100 m 100Ω 10nF Safety output P channel FET 02 Instantaneous 4 3 03 3 03 Off delay 04 2 03 2 03 Time accuracy 5 5 Load current Below 2 point output DC 1 A Over 3 point output DC 0 8 A Leakage current 0 1 mA Operating time OFF ON 05 Safety input 50 ms Logic input...

Page 3: ...tors Model SFC SFC A SFC N SFC ER SFC R 12 SFC R212 R2 PWR green Power M1 white Safety input 1 ㅡ M2 white Safety input 2 ㅡ NS white Non contact door switch input ㅡ ㅡ ㅡ ㅡ ㅡ AND white Logic input ㅡ ㅡ ㅡ ㅡ ERR red Error FB white Feedback start input ㅡ OUT1 green Instantaneous safety output OUT2 green Off delay safety output ㅡ ㅡ ㅡ Installation Mounting with bolts 1 Pull each rail locks to up and down a...

Page 4: ...F state The duration that the start switch is in the ON state min 100 ms Feedback loop Start switch 24 VDCᜡ M61 M62 Logic input Connect the safety outputs of the upper unit to the logic AND input of the lower unit To use the logic input function SW1 and SW2 of switch for setting function must be set to ON state Up to four units advanced non contact door switch unit can be connected as logic AND co...

Page 5: ...tting value of the switch for off delay time Flash Error at internal circuit and output relay of the expansion relay unit Please contact the Autonics OFF M1 M2 flashes The different input signal between safety input 1 and safety input 2 Check the wiring to the safety input devices Check the input sequence of safety inputs CheckandMaintenance Check installation conditions Checklist Check 1 The dist...

Page 6: ...9 e 4 218 18 year 99 00 SFC A322 23 L SFC A322 2300 4 99 00 SFC A322 2300 L SFC N SFC N322 23 SIL 3 7 36E 09 e 4 183 67 year 99 00 SFC N322 23 L SFC N322 2300 4 99 00 SFC N322 2300 L SFC R SFC R212 SIL 3 5 29E 09 e 4 247 78 year 99 00 SFC R212 L SFC R412 4 99 00 SFC R412 L SFC R212 R23 4 99 00 SFC R212 R23 L SFC R212 R230 4 99 00 SFC R212 R230 L FailureRate ...

Page 7: ...1 Safety Input 2 Feedback Start Input Auxiliary Output Logic Input Safety Output SW1 Safety light curtain MC1 to MC4 Contactor M1 M2 3 phase motor Motor Controller Control Signal Motor Controller Operation timing chart MC3 MC4 a contact MC3 MC4 b contact MC1 MC2 a contact MC1 MC2 b contact Safety light curtain SW1 Motor controller control signal Rotation of M2 motor Off delay time For more informa...

Page 8: ...ntroller Advanced unit Power Expansion Output Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Logic Input Safety Output PLC etc Motor controller Motor Controller Control Signal Expansion Output Expansion Input Power Auxiliary Output Safety Relay Output Safety controller Expansion relay unit PLC etc SW1 Lock release switch SW2 Safety door lock switch SW3 Safety limit switch SW4 ...

Page 9: ... Input Safety controller Non contact door switch unit PLC etc Motor Controller Actuator SFN Series Safety Non Contact Door Switch White Black Brown Blue Motor Controller Control Signal SW1 Lock release switch SW2 Safety door lock switch SW3 Safety limit switch SW4 Safety emergency stop switch SW5 Safety non contact door switch MC1toMC2 Contactor M1 Motor Operation timing chart M1 Rotation of motor...

Page 10: ...Start Input Auxiliary Output Logic Input Safety Output Expansion Output Non Contact Door Switch Input Safety controller Non contact door switch unit PLC etc Actuator SFN Series Safety Non Contact Door Switch White Black Brown Blue Motor Controller Control Signal PLC etc Operation timing chart Safety controller Basic unit Safety controller Non contact door switch unit Start switch SW2 Safety emerge...

Page 11: ... Safety controller Relay unit Feedback Start Input Auxiliary Output Safety Relay Output Power Safety Input 1 Safety Input 2 PLC etc SW1 Safety emergency stop switch SW2 Start switch MC1 MC2 Contactor M1 3 phase motor Operation timing chart M1 Rotation of motor MC1 MC2 a contact MC1 MC2 b contact Safety emergency stop switch SW1 Start switch SW2 When you do not use the logic input M61 M62 set the s...

Page 12: ...mitter SFL A Series Receiver OSSD1 OSSD2 NC NC 24V GND MC1 MC2 MC3 MC4 MC3 MC4 M2 MC3 MC4 MC1 to MC4 Magnetic contactor M1 M2 3 phase motor Safety controller Relay unit PLC etc Power Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Safety Relay Output Operation timing chart MC1 to MC4 b contact MC1 to MC4 a contact Safety light curtain For more information on wiring and detailed...

Page 13: ...1 SW1 Unlock signal SW4 SW2 MC2 MC1 SW3 MC1 MC2 M1 MC1 MC2 GND GND 24V PLC etc SW1 Safety limit switch SW2 Safety door lock switch SW3 Feedback start switch SW4 Unlock switch MC1 to MC4 Magnetic contactor M1 M2 3 phase motor Safety controller Relay unit Off Delay Power Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Safety Relay Output Instantaneous Operation timing chart Off d...

Reviews: