Autonics SFC Series Manual Download Page 12

-|Transparent Guide|-

Connection Examples 6

  

■ Relay unit-Safety light curtain

Connections

Start

PL/Safety category

Safety controller: Relay unit SFC-R412

Safety light curtain:   SFL / SFLA Series

Contactor of rated load  (from Annex C of ISO 13849-1)

Auto

PLe/Cat.4 equivalent

M1

2

M11

A2

A1

M5

2

M51

M22

M2

1

M5

3

FUSE

X1

34

33

24

44

43

23

14

13

MC

1

MC2

GN

D

M1

MC

1

MC2

SFL(A) Series

Emit

te

r

SFL(A) Series

Re

ceiver

OSSD1

OSSD

2

NC

NC

24

V

GN

D

MC

1

MC2

MC3

MC4

MC3

MC4

M2

MC3

MC4

MC1 to MC4: Magnetic contactor

M1, M2: 3-phase motor

Safety controller: Relay unit

PLC etc.

Power

Safety Input 1

Safety Input 2

Feedback

Start Input

Auxiliary Output

Safety Relay Output

• 

Operation timing chart

MC1 to MC4 b contact

MC1 to MC4 a contact

Safety light 

curtain 

• 

For more information on wiring and detailed settings for safety light curtain (SFL/SFLA Series), see the “

SFL/SFLA user manual.”

• 

The control output of the safety light curtain (SFL(A) series) is based on the PNP output.

Summary of Contents for SFC Series

Page 1: ...th the machine control system it may cause malfunction or result in accidents 04 When the connected devices e g motor is not operating after installation check that functions and settings of the product correctly operate as you intended Failure to follow this instruction may result in personal injury economic loss or fire 05 Be sure to consider the delay of the safety output when determining the s...

Page 2: ... voltage Power consumption 01 2 5 W 3 0 W 3 5 W Input ON 11 VDCᜡ 5 mA OFF 5 VDCᜡ 1 mA Input time 50 ms feedback start manual 100 ms Cable 100 m 100Ω 10nF Safety output P channel FET 02 Instantaneous 4 3 03 3 03 Off delay 04 2 03 2 03 Time accuracy 5 5 Load current Below 2 point output DC 1 A Over 3 point output DC 0 8 A Leakage current 0 1 mA Operating time OFF ON 05 Safety input 50 ms Logic input...

Page 3: ...tors Model SFC SFC A SFC N SFC ER SFC R 12 SFC R212 R2 PWR green Power M1 white Safety input 1 ㅡ M2 white Safety input 2 ㅡ NS white Non contact door switch input ㅡ ㅡ ㅡ ㅡ ㅡ AND white Logic input ㅡ ㅡ ㅡ ㅡ ERR red Error FB white Feedback start input ㅡ OUT1 green Instantaneous safety output OUT2 green Off delay safety output ㅡ ㅡ ㅡ Installation Mounting with bolts 1 Pull each rail locks to up and down a...

Page 4: ...F state The duration that the start switch is in the ON state min 100 ms Feedback loop Start switch 24 VDCᜡ M61 M62 Logic input Connect the safety outputs of the upper unit to the logic AND input of the lower unit To use the logic input function SW1 and SW2 of switch for setting function must be set to ON state Up to four units advanced non contact door switch unit can be connected as logic AND co...

Page 5: ...tting value of the switch for off delay time Flash Error at internal circuit and output relay of the expansion relay unit Please contact the Autonics OFF M1 M2 flashes The different input signal between safety input 1 and safety input 2 Check the wiring to the safety input devices Check the input sequence of safety inputs CheckandMaintenance Check installation conditions Checklist Check 1 The dist...

Page 6: ...9 e 4 218 18 year 99 00 SFC A322 23 L SFC A322 2300 4 99 00 SFC A322 2300 L SFC N SFC N322 23 SIL 3 7 36E 09 e 4 183 67 year 99 00 SFC N322 23 L SFC N322 2300 4 99 00 SFC N322 2300 L SFC R SFC R212 SIL 3 5 29E 09 e 4 247 78 year 99 00 SFC R212 L SFC R412 4 99 00 SFC R412 L SFC R212 R23 4 99 00 SFC R212 R23 L SFC R212 R230 4 99 00 SFC R212 R230 L FailureRate ...

Page 7: ...1 Safety Input 2 Feedback Start Input Auxiliary Output Logic Input Safety Output SW1 Safety light curtain MC1 to MC4 Contactor M1 M2 3 phase motor Motor Controller Control Signal Motor Controller Operation timing chart MC3 MC4 a contact MC3 MC4 b contact MC1 MC2 a contact MC1 MC2 b contact Safety light curtain SW1 Motor controller control signal Rotation of M2 motor Off delay time For more informa...

Page 8: ...ntroller Advanced unit Power Expansion Output Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Logic Input Safety Output PLC etc Motor controller Motor Controller Control Signal Expansion Output Expansion Input Power Auxiliary Output Safety Relay Output Safety controller Expansion relay unit PLC etc SW1 Lock release switch SW2 Safety door lock switch SW3 Safety limit switch SW4 ...

Page 9: ... Input Safety controller Non contact door switch unit PLC etc Motor Controller Actuator SFN Series Safety Non Contact Door Switch White Black Brown Blue Motor Controller Control Signal SW1 Lock release switch SW2 Safety door lock switch SW3 Safety limit switch SW4 Safety emergency stop switch SW5 Safety non contact door switch MC1toMC2 Contactor M1 Motor Operation timing chart M1 Rotation of motor...

Page 10: ...Start Input Auxiliary Output Logic Input Safety Output Expansion Output Non Contact Door Switch Input Safety controller Non contact door switch unit PLC etc Actuator SFN Series Safety Non Contact Door Switch White Black Brown Blue Motor Controller Control Signal PLC etc Operation timing chart Safety controller Basic unit Safety controller Non contact door switch unit Start switch SW2 Safety emerge...

Page 11: ... Safety controller Relay unit Feedback Start Input Auxiliary Output Safety Relay Output Power Safety Input 1 Safety Input 2 PLC etc SW1 Safety emergency stop switch SW2 Start switch MC1 MC2 Contactor M1 3 phase motor Operation timing chart M1 Rotation of motor MC1 MC2 a contact MC1 MC2 b contact Safety emergency stop switch SW1 Start switch SW2 When you do not use the logic input M61 M62 set the s...

Page 12: ...mitter SFL A Series Receiver OSSD1 OSSD2 NC NC 24V GND MC1 MC2 MC3 MC4 MC3 MC4 M2 MC3 MC4 MC1 to MC4 Magnetic contactor M1 M2 3 phase motor Safety controller Relay unit PLC etc Power Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Safety Relay Output Operation timing chart MC1 to MC4 b contact MC1 to MC4 a contact Safety light curtain For more information on wiring and detailed...

Page 13: ...1 SW1 Unlock signal SW4 SW2 MC2 MC1 SW3 MC1 MC2 M1 MC1 MC2 GND GND 24V PLC etc SW1 Safety limit switch SW2 Safety door lock switch SW3 Feedback start switch SW4 Unlock switch MC1 to MC4 Magnetic contactor M1 M2 3 phase motor Safety controller Relay unit Off Delay Power Safety Input 1 Safety Input 2 Feedback Start Input Auxiliary Output Safety Relay Output Instantaneous Operation timing chart Off d...

Reviews: