Parameter Setting
Parameter 2 group
Parameter name
Setting range
Description
Factory
default
SUB
SV display part
STD
UNIT
OFF
Standard
Unit
OFF
Select the display type at the SV display part in RUN mode.
Standard [
STD
]: Display setting value (SV) always.
Unit [
UNIT
]: Display pressure unit normally. When pressing , key,
display setting value (SV) for 5 sec.
None [
OFF
]: It does not display any value normally. When pressing ,
key, display setting value (SV) for 5 sec.
※
If select unit [
UNIT
] or None [
OFF
], changing setting value (SV) is
available when setting value is displayed.
STD
COPY
Parameter copy
OFF
ON
ON-L
OFF
ON
ON with key lock
This function is for copying parameter settings of Master to Slave 1:1.
※
For the details, refer to '
▣
Functions -
◎
Paprameter Copy'.
OFF
INIT
Parameter reset
OFF
ON
OFF
Reset parameter setting
Reset the parameter settings.
OFF
PWD
Password
0000
to
9999
-
Set the 4-digit password.
[
0000
]: Disable password
[
0001
]: Only checking parameters
0000
sOUT
Control output
switching
NPN
PNP
NPN
PNP
Select type of control output.
NPN
HYS
Hysteresis for
easy mode
1
to
11111111
Bar type
(Min: 1ea , Max: 8ea)
Set the hysteresis for easy mode.
Rated pressure range
Hysteresis per 1 Bar
-100.0 to 100.0kPa
0.1kPa
-100.0 to 1,000kPa
1kPa
※
Appears when OUT1 or OUT2 operation mode is easy mode.
※
Although the display unit is changed, standard unit of
hysteresis for
easy mode
is not changed.
111
High/Low Peak Hold
※
Clearing Max./Min. pressure value.
1.
Press the
M
+
key for over 1 sec in RUN mode
and set the
peak hold.
2. High peak is displayed on present value (PV)
display, and low peak is displayed on setting value
(SV) display.
3.
Press the + key for over 1 sec, initialize high/
low peak value.
Clearing Max./Min. pressure value
Retained maximum and minimum
pressure value will flash every 0.5 sec
M
+
for over 1 sec
+
for over 1 sec
※
When the memorized Max. pressure is higher
than the rated pressure, it displays
HHHH
.
When it is lower than the rated pressure,
it displays
LLLL
.
Analog Output Scale Adjustment
only for NPN or PNP open collector analog output or external input type model
Output
PV
A-04
A-20
20mA
21.6mA
4mA
2.4mA
10%
F.S.
10%
F.S.
Output
PV
A-1V
A-5V
5VDC
5.4VDC
1VDC
0.6VDC
10%
F.S.
10%
F.S.
This function is to diagnose malfunction of the system caused by parasitic pressure through memorizing input the max./min. pressure
occurred from the system.
M