G-18
PSQ Series
Output Operation Mode
Window comparison output mode [
WIN
]
It detects pressure at the desired range.
Set high-limit value of
pressure detection level [
HI1
,
HI2
], and
low-limit value
of
pressure detection level [
LO1
,
LO2
].
Hysteresis is fixed as Min. display interval.
Time
Time
Time
Time
Time
Pressure
ON
OFF
ON
OFF
ON
OFF
ON
OFF
※
1: Min. display interval
※
1
※
1
※
1
※
1
HI2
HI1
LO2
LO1
LO1
/
HI1
LO1
/
HI1
LO2
/
HI2
LO2
/
HI2
OUT1 N.O.
OUT2 N.O.
OUT1 N.C.
OUT2 N.C.
Auto sensitivity setting mode [
AUTO
]
It sets the proper detection sensitivity automatically.
It sets by the two
pressure
points
[
ST1
,
ST2
].
Hysteresis is fixed as Min. display interval.
The pressure detection level [
SET
] is shown in the below formula.
(
ST1
+
ST2
)
2
SET
=
Pressure
※
1:
Min. display interval
※
1
※
1
※
1
ST1
/
ST2
SET
SET
ST1
/
ST2
OUT1 N.O.
OUT2 N.O.
OUT1 N.C.
OUT2 N.C.
ST2
SET
ST1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Time
Time
Time
Time
Time
Forced output control mode [
fOUT
]
RUN mode
fOUT
Regardless of setting value, it maintains comparison output OFF
and displays present pressure.
Set OUT1 operation mode [
OUT1
] of parameter 1 group as
[
fOUT
] and return to RUN mode. The PV display part displays the
measured pressure and the SV display part displays [
fOUT
].
During forced output control mode, press the
or
key to turn
ON/OFF
OUT1, 2 manually.
RUN mode
RUN mode
RUN mode
Forced output
control mode
OUT1
OUT2
Time
ON
OFF
ON
OFF
M
M
Time
M
M