Proper Usage
Caution
Caution
1. Pressure port is divided as standard and option
specification. Therefore, make sure use commercially
available one touch fitting.
● Pneumatic type: Rc1/8, R1/8, NPT1/8
● Fluid type: Rc1/8, R1/8, R1/4, NPT1/4, 9/16-18UNF
2.
U
se a spanner (pneumatic type: 12mm, fluid type: 17mm)
at the metal part of the unit in order not to overload on
the body when connecting one touch fitting.
3. Two different brackets are provided for pneumatic type
and one different brackets are provided for fluid type.
Select proper one with considering your application
environments.
4.
At first, please unscrew hexagon wrench bolt and
assemble the bracket on this unit by fixing hexagon the
wrench bolt.
In this case, tightening torque of hexagon wrench
should be max. 3N.m. It may cause mechanical
problems.
ᆞ
12-24VDC model, power supply should be insulated and
limited voltage/current or Class 2, SELV power supply
device.
ᆞ
Do not insert any sharp or pointed object into pressure
port. Failure to follow these instructions may result in
malfunction and damage to the sensor.
ᆞ
Be sure that this unit must avoid direct touch with water,
oil, thinner, etc.
5. PSQ Series has panel bracket (PSO-B02),
front cover (PSO-P01) are sold separately.
When mounting the unit on panel, please follow the
below figure.
The tightening torque of one touch fitting should be
max. 10N.m. It may cause mechanical problems.
Front cover
(PSO-P01)
Mounting panel
(panel thickness 0.8~3.5mm)
Panel bracket
(PSO-B02)
Body
(PSQ)
SMPS
+
F.G.
-
ᆞ
Do not use the product in preparation time (within 3 sec).
for operating after power-on.
ᆞ
When using switching mode power supply, frame ground
(F.G.) terminal of power supply should be grounded.
ᆞ
Avoid wiring with power line or high voltage line.
It may cause malfunction by noise.
ᆞ
When moving this unit from cold place to warm place,
please remove the humidity on the cover.
ᆞ
Do not press the setting button with sharp or pointed
object.
ᆞ
Do not apply a tensile strength in excess of 30N to the
cables or connector.
ᆞ
This unit may be used in the following environment.
①
Indoors
②
Altitude max. 2,000m
③
Pollution degree 3
④
Installation category II
PSQ Series is for sensing of non corrosive gas.
Do not use this product at corrosive gas or flammable
gas, etc.
12mm
spanner
17mm
spanner
<
Pneumatic type
>
<
Fluid type
>
Bracket C
Spring washer
Hexagon wrench
bolt (M3×6)
Bracket A
Bracket B
<
Pneumatic type
>
<
Fluid type
>
When using separate installation set
6. Do not pull the cable with a tensile strength of 30N or over.
Body
(PSQ)
Front cover
(PSO-P02)
Front panel bracket
(PSO-B04)
Rear panel bracket
(PSO-B04)
Mounting panel
(panel thickness: 0.5 to 7mm)
When using integrated installation set
<
Pneumatic/Fulid type
>
<
Pneumatic type
>