50
MCS Manual Rev. 1.4
Description of Modes for Triggering the Sequencer/Frame and
Profile Acquisition
No. Sequencer/Frame Trigger Mode
Profile Trigger
Mode (PTM)
0
Free-run
PTM0 (free-run)
PTM1 (IN1)
PTM2 (IN2)
1
Start/stop over camera input 1/2
Continuous frame acquisition is started with the rising edge
of camera input 1 (IN1) and stopped with rising edge of
camera input 2 (IN2).
When “stop” occurs, the frame is not transmitted
immediately over the GigE interface but the sensor continues
to acquire profile data, until the predefined frame height is
reached.
PTM0 (free-run)
PTM3 (RS422)
2
Trigger one frame over camera input 1
Single frame acquisition is triggered over the rising edge of
camera input 1 (IN1).
PTM0 (free-run)
PTM2 (IN2)
PTM3 (RS422)
trigger start of sequencer
(frame trigger)
t
trigger stop of sequencer
trigger start of sequencer
(frame trigger)
t
IN1
Summary of Contents for MCS 1280 Series
Page 1: ...er MCS Manual Rev 1 4 User Manual for MCS cx1280 MCS cx2040 MCS cx4090...
Page 2: ......
Page 20: ...18 MCS Manual Rev 1 4 Mechanical Drawings Housing Types 1 4 2 5 3 6...
Page 21: ...MCS Manual Rev 1 4 19 Dimensions Housing Type 1 and 2 All dimensions in mm...
Page 23: ...MCS Manual Rev 1 4 21 Housing Type 3 All dimensions in mm...
Page 60: ...58 MCS Manual Rev 1 4...
Page 63: ...MCS Manual Rev 1 4 61 Mechanical Dimension All dimensions in mm Mount for DIN rail assembly...
Page 65: ...MCS Manual Rev 1 4 63 I O and Encoder with Differential HTL Mode for RS422 Option...
Page 66: ...64 MCS Manual Rev 1 4 I O and Encoder with Single Ended HTL or TTL Mode for RS422 Option...
Page 89: ...MCS Manual Rev 1 4 87...
Page 93: ...Automation Technology GmbH All rights reserved Subject to change without prior notification...