48
MCS Manual Rev. 1.4
Trigger Control
–
RS422 Resolver
The
TriggerCoord
node always counts all the raw trigger signals arriving at the camera
-> rising AND falling edge!
The
TriggerDivider
is used internally by the camera. The camera doesn’t change its behavior if the
TriggerDivider
is set to another value. A
TriggerDivider
of 10 for example will use every tenth incoming trigger for one profile measurement.
If single-ended encoder signals are required it is set over
TriggerSingleChannelMode
.
Triggering over Channel A or B or over Input1 and Input2 is then
possible.
If other encoder signals than RS422 are needed, use the Inputs of the camera instead of the encoder inputs and set
UseAlternateResolverInputs
to
true
.
Name
Interface
Access Visibility Description
TriggerDivider
(*)
IInteger
RW
Beginner Trigger divider
Min: 1
Max: 65535
Increment: 1
TriggerCoord
IInteger
RO
Beginner Trigger coordinate
TriggerDirectionMode
IBoolean
RW
Beginner Count resolver pulses in both directions
TriggerReverseDirection
IBoolean
RW
Beginner Reverse the resolver count direction
TriggerSingleChannelMode
(*)
IEnumeration RW
Guru
Enable resolver in single channel mode
(1): Disabled (Value= 0)
(2): EnableIn1 (Value= 1)
(3): EnableIn2 (Value= 2)
TriggerDividerLoadAtStart
(*)
IBoolean
RW
Beginner Load trigger divider upon start trigger
LoadTriggerDivider
(*)
ICommand
WO*
Beginner Load trigger divider
ClearTriggerCoord
ICommand
WO*
Beginner Reset trigger coordinate
ResetTriggerCoordZeroPos
IEnumeration RW
Beginner Reset the Trigger Coordinate/Counter at Zero Position (Index, Z-Channel)
Summary of Contents for MCS 1280 Series
Page 1: ...er MCS Manual Rev 1 4 User Manual for MCS cx1280 MCS cx2040 MCS cx4090...
Page 2: ......
Page 20: ...18 MCS Manual Rev 1 4 Mechanical Drawings Housing Types 1 4 2 5 3 6...
Page 21: ...MCS Manual Rev 1 4 19 Dimensions Housing Type 1 and 2 All dimensions in mm...
Page 23: ...MCS Manual Rev 1 4 21 Housing Type 3 All dimensions in mm...
Page 60: ...58 MCS Manual Rev 1 4...
Page 63: ...MCS Manual Rev 1 4 61 Mechanical Dimension All dimensions in mm Mount for DIN rail assembly...
Page 65: ...MCS Manual Rev 1 4 63 I O and Encoder with Differential HTL Mode for RS422 Option...
Page 66: ...64 MCS Manual Rev 1 4 I O and Encoder with Single Ended HTL or TTL Mode for RS422 Option...
Page 89: ...MCS Manual Rev 1 4 87...
Page 93: ...Automation Technology GmbH All rights reserved Subject to change without prior notification...