66
MCS Manual Rev. 1.4
Master/Slave Connection
The following schematic shows the required wiring to operate two compact sensors or one dual head
sensor in a Master/Slave mode. For this purpose the OUT2 of the master sensor is exemplary
connected to the trigger input IN1 of the slave sensor. The Master/Slave mode can be realized with
both inputs (IN1/IN2) and outputs (OUT1/OUT2).
Example configurations for Master/Slave Connections
Two compact sensors to eliminate laser interference
OUT2
IN1
t
t
Exposure max
200µs
Exposure max
200µs
Frame Period 400µs
Frame Period 400µs
MASTER
f=2500 Hz
SLAVE
f=2500 Hz
Triggered after
exposure of
Master Sensor
The falling edge of
Master OUT2
generate a slave
profile trigger
Use Registers:
Master:
Output2 = Out2_IntegrationActive
Output2Invert = true
Slave:
ProfileTriggerMode = CameraInput1
Summary of Contents for MCS 1280 Series
Page 1: ...er MCS Manual Rev 1 4 User Manual for MCS cx1280 MCS cx2040 MCS cx4090...
Page 2: ......
Page 20: ...18 MCS Manual Rev 1 4 Mechanical Drawings Housing Types 1 4 2 5 3 6...
Page 21: ...MCS Manual Rev 1 4 19 Dimensions Housing Type 1 and 2 All dimensions in mm...
Page 23: ...MCS Manual Rev 1 4 21 Housing Type 3 All dimensions in mm...
Page 60: ...58 MCS Manual Rev 1 4...
Page 63: ...MCS Manual Rev 1 4 61 Mechanical Dimension All dimensions in mm Mount for DIN rail assembly...
Page 65: ...MCS Manual Rev 1 4 63 I O and Encoder with Differential HTL Mode for RS422 Option...
Page 66: ...64 MCS Manual Rev 1 4 I O and Encoder with Single Ended HTL or TTL Mode for RS422 Option...
Page 89: ...MCS Manual Rev 1 4 87...
Page 93: ...Automation Technology GmbH All rights reserved Subject to change without prior notification...