Menu 6.2 PE Beams Input Response Mode
The PE Beams input can be confi gured to respond in one of three modes.
Reverses Close Cycles
In this mode, the PE Beams input has no effect when opening but will cause the door to reverse if activated
when closing.
Close Cycles Stop
In this mode, the PE Beams input has no effect when opening but will stop the door when closing.
Open and Close Cycles Stop
In this mode, all cycles are prevented from being completed or initiated when the PE Beams input is active.
Menu 6.3 PE Beams Obstruction Reverse Time Mode
Normally after a PE Beams obstruction the door will fully open to its open position. After a PE Beam Close
obstruction, the doors open cycle can be reduced from 5 sec to its full open position.
Menu 6.4 Pe Beams Type
GDO-10v2 supports EasyBeam™ or three wire beams.
Menu 6.5 GPI Input
GPI input can be confi gured as OSC, PED or DST setup. The GPI input terminal is activated by the N/O switch.
When GPI Selected As OSC:
If the door is moving, the activation of the GPI input or by a transmitter button with the OSC function assigned
will cause the door to stop. The next trigger will move the door in the opposite direction to the last travelled.
When GPI Input Is Confi gured As PED:
The activation of the GPI input or by a transmitter button with PED function assigned will open the door partially
to allow pedestrian access but prevent vehicle access. The position the door is driven to is automatically set to
halfway during setting of the travel limits, but can be adjusted to suit.
When GPI Input Is Confi gured As DST:
The GPI input can be used to switch between STD time and DST (daylight savings time). The time selected is the
amount of time added to STD time when DST is selected. The Options are OFF, 30, 60, 90 or 120 minutes. The
GPI input needs to be constantly active to show day light saving time.
Menu 6.6 PED Input Function
If GPI or Fire Input is selected as PED then these inputs can be confi gured to a SWIPE type input for pedestrian
access. This provides full functionality with the PE Beams Triggered Pedestrian Auto-Close function.
Menu 6.7 Open Input Polarity
The OPN input is normally confi gured for N/O operation. This parameter allows its operation to be changed to
N/C.
Menu 6.8 Open Input As A Second PE Beams Input
Selecting this parameter will allow the OPN input to be used as a second PE Beams input. When the OPN input
is active, the door is prevented from being closed. If the OPN input is triggered while the door is closing, the
controller will stop the motor and then open the door. The OPN input has no effect while the door is opening.
The second PE Beams (OPN) input must be active when the PE Beams input is activated in order for PE Beams
Triggered Auto-Close to be activated.
Menu 6.9 STP Input Polarity
The STP input is normally confi gured for N/O operation. This parameter allows its operation to be changed to
N/C.