Standard Operating Modes
Motor Speed Control - SOFT START/SOFT
STOP
The motor’s speed is microprocessor controlled,
ramping up speed as the door starts to move,
and ramping down as it approaches the travel
limits to provide a gentle stop.
Lock Release Output
The lock release output is confi gured to pulse for
the time set by the controller at the start of each
cycle. The output is turned on at the same time
the motor is activated.
Courtesy Light
Courtesy lights can be connected using light
relays N/O or N/C output. Normally used as a
safety device to illuminate the area and warn
pedestrians, the light will turn on each time the
door is activated (day or night) and automatically
turn off one (1) minute after the cycle has fi nished.
The light timer is adjustable. The light can also
be activated and deactivated by pressing a
transmitter button assigned the LGT function.
Photo electric (PE) EasyBeam™ Input
When the EasyBeam™ input is active, the door is
prevented from being closed. If the EasyBeam™
input is triggered while the door is closing, the
controller will stop the motor and then open the
door. The EasyBeam™ input has no effect while
the door is opening.
OPN input can also be confi gured as a second PE
Beam input. The second PE (OPN) input must be
active when the EasyBeam™ is activated in order
for P.E triggered Auto-Close to be activated .
Fire (FIRE) Input
Fire input can be confi gured as OPN ,CLS or PED
function. The FIRE input terminal is activated with
the N/O or N/C switch.
When Fire Input Is Confi gured As OPN :
Activating the fi re input will cause the door to
open. Holding the input will prevent door from
closing.
When Fire Input Is Confi gured As CLS :
Activating the fi re input will cause the door to
close. Holding the input active will prevent door
from opening.
When Fire Input Is Confi gured As PED:
The activation of the fi re input opens the door
to partially allow pedestrian access but prevent
vehicle access. The position the door is driven
to is automatically set to halfway during setting
of the travel limits, but can be adjusted to suit.
GPI (General Purpose Input)
General purpose input can be confi gured as OSC,Ped
or day light saving setup. The GPI input terminal is
activated with the N/O switch.
When GPI Selected As OSC :
If the door is moving, the activation of the GPI input or
a transmitter button with the OSC function assigned
will cause the door to stop. The next trigger will move
the door in the opposite direction to that last travelled.
When GPI Input Is Confi gured As PED :
The activation of the GPI input or a transmitter
button with PED function assigned will open the door
partially to allow pedestrian access but prevent
vehicle access. The position the door is driven to is
automatically set to halfway during setting of the
travel limits, but can be adjusted to suit.
When GPI Input Is Confi gured As Day Light
Saving:
The GPI input can be used to switch between STD time
and DST (daylight savings time). The time selected is
the amount of time added to STD time when DST is
selected.
Options are OFF, 30, 60, 90 or 120 minutes. The GPI
input needs to be constantly active to show day light
saving time.
Open (OPN) Input
(Activated by OPN terminal with N/O or N/C switch,
a transmitter button with OPN function assigned or
by OPEN button on the console). Activating the OPN
input will cause the door to open. Holding the input
will prevent door from closing. OPN input can also be
confi gured as second P.E Beams input.
Stop (STP) Input
(Activated by STP terminal with N/O or N/C switch, a
transmitter button with STP function assigned or by
STOP button on the console). Activating the STP input
while the door is moving will cause the door to be
stopped. If the STP terminal is held, it will prevent the
door from being moved.
Close (CLS) Input
(Activated by CLS terminal with N/O switch, a
transmitter button with CLS function assigned or by
CLOSE button on the console). Activating the CLS
input will cause the door to close. Holding the input
active will prevent opening.
Swipe Card (SWP) Input
(Activated by SWP terminal with N/O switch or a
transmitter button with SWP function assigned).
Activating the SWP input will cause the door to be
opened. If the terminal input is held, it will prevent
the door being closed. The swipe input also effects PE
Beams TRIGGERED AUTO-CLOSE.