16
GDO-10V2 Toro
™
Owner Installation Instructions
Viewing and Editing Parameters
This section illustrates how to locate, view and
adjust parameters.
Locating parameters
Refer to MENU STRUCTURE on Page 15 or the preceding
section for CONTROL BOARD ADJUSTMENTS. Locate
the required parameter and note the MENU number.
The example used in
(Fig. 12)
displays “CLOSE LOCK
TIME”
Changing Setting
1. Press NEXT/PREV to navigate to the required menu.
2. Press SET to show the sub-menu.
3. Press NEXT/PREV to go to the required sub-menu.
4. Press OPEN/CLOSE to change parameter setting.
Holding the button down causes the parameter’s
value to change rapidly. The longer the button is
held the faster the value changes.
5. Press SET to SAVE setting.
Reload Default Setting
1. Press NEXT/PREV buttons to display LOAD
DEFAULT screen.
2. Press SET to load the default value.
Return To Menu
If the parameter’s value is not to be changed, press
STOP to return to the sub menu. Press STOP again to
return to the MAIN SCREEN.
12
fi g
2: Close Lock
Time (sec) 0.5
13
fi g
2: Close Lock
Time (sec) 0.
∆
Parameter name
Parameter
value
Displays next
parameter
in list
Parameter number in sub menu
Displays
previous
parameter in list
Returns back to menu
Enter Edit Mode
View Mode (No cursor)
Edit Mode (Cursor shown)
Increase
value
Displays “Load
Default?” screen,
giving option of
loading default value
Exits back to View Mode
Decrease
value
Saves new
value
Cursor shown