Owner Installation Instructions
GDO-10V2 Toro
™
29
Standard Operating Modes
Parameter
Min
Max
Default
Step
Unit
Menu No.
OPEN SPEED VOLTAGE
Sets the full speed motor voltage
~12.0
~24
~22
~1
Volts
6
CLOSE SPEED VOLTAGE
Sets the full speed motor voltage
~12.0
~24
~20
~1
Volts
6
The standard operation of the opener can be altered by editing various parameters. This section
describes the parameters and the effect they have. Use the VIEWING AND EDITING PARAMETER
PROCEDURE on Page 16 to make changes.
Menu 2.3 Door Reverse Time After Close Obstruction
Normally after a close obstruction, the door will fully open to its open position. After a close obstruction, the open
cycle can be reduced from 5 seconds to its full open position.
Parameter
Min
Max
Default
Step
Unit
Menu No.
Reverse Time After Close Obstruction
5.0
Fully
Open
Fully
Open
1
Sec
2.3
Menu 5. Motor Settings
Motor speed
The maximum speed the motors run at is controlled by the OPEN AND CLOSE SPEED VOLTAGE parameter.
The default value is the maximum recommended for normal operation. If however the door moves too quickly
for a particular installation, the voltage can be reduced to make the motors run slower.
NOTE:
Altering these
parameters will cause the travel limits to be cleared.
Control Board Adjustments
Vacation Mode
Vacation Mode blocks all but one designated remote control transmitter from activating the
GDO-10v2
opener.
The mode is activated by pressing a transmitter button with the VAC function assigned until the console displays
that Vacation Mode is enabled (approx. 5 secs). When activated all the transmitter buttons will be ignored. To turn
Vacation Mode off press a transmitter button with the VAC function assigned. Vacation Mode can also be turned on
or off manually by editing the Vacation Mode parameter.
Menu 6. Operating Modes
Menu 6.1 Safety Close Mode
By enabling this parameter, the user can close the door only by holding the close button on the wall control unit or by
holding the CLS input active. The door can not be closed by Auto-Close or by transmitters. If the PE Beams are not
installed, the controller will be loaded with Safety Close Mode and the following message will be displayed:
ATTENTION! “SAFETY CLOSE MODE has been enabled as no P.E beam has been
installed! This means that the door can only be closed by HOLDING the ‘CLS input’ or
‘CLOSE button’. All other means of closing the door are disabled. Press SET to continue. “