Owner Installation Instructions
NeoSlider
TM
- Sliding Gate Opener NES-24V3
23
Parameter
Option
Default
Menu
Section
Menu 7 - Operating Modes
SB1 TYPE
2 WIRE
3 WIRE
2 WIRE
7.1
Appendix D
SB2 TYPE
2 WIRE
3 WIRE
2 WIRE
7.2
Appendix D
SB1 INPUT MODE
Sets the Input mode for Safety Beam 1.
Only one option can be selected.
NOT USED, CLS TO REV
CLS TO STOP OPN/CLS TO STOP
OPEN INPUT SWIPE INPUT
CLOSE INPUT PED INPUT
DISABLED
NOT USED
7.3
Appendix D
SB2 INPUT MODE
Sets the Input mode for Safety Beam 2.
Only one option can be selected.
NOT USED, CLS TO REV
CLS TO STOP OPN/CLS TO STOP
OPEN INPUT SWIPE INPUT
CLOSE INPUT PED INPUT
DISABLED
NOT USED
7.4
Appendix D
PED INPUT = SWIPE MODE Selects PED
input functions as pedestrian access swipe
input
Off
Off
7.5
Appendix D
OPN INPUT N/C OPERATION
Selects operating polarity of OPN input
Off
Off
7.6
Appendix D
STP INPUT N/C OPERATION
Selects operating polarity of STP input
Off
Off
7.7
Appendix D
REMOTE CODE ENABLED
Selects remote transmitter coding function
On
On
7.8
Appendix D
VACATION MODE
Selects vacation mode - disables remote
control
Off
Off
7.9
Appendix D
BATTERY/SOLAR MODE
Selects Battery Backup/Solar operation
BATTERY ENABLED
SOLAR ENABLED
BATTERY
ENABLED
7.10
Appendix D
PASSWORD
Selects password protection for all changes
Off
Off
7.11
Appendix D
TX # GROUPING
Selects transmitter number group display
format.
Off
Off
7.12
Appendix D
OUTPUTS 1 MODE
Selects function of OUTPUT1
LOCK DRIVE LIGHT DRIVE
3 WIRE SB 0V NOT USED
7.13
Appendix D
OUTPUTS 2 MODE
Selects function of OUTPUT2
LOCK DRIVE LIGHT DRIVE
3 WIRE SB 0V NOT USED
7.14
Appendix D
FAULT AUTO RESET
Off
Off
7.15
Appendix D
SBFEC MODE
AVAILABLE
DISABLED
AVAILABLE
7.16
Appendix D
A - Console Menu Structure
Appendix
Parameter
Option
Default
Menu
Section
Menu 8 - Diagnostics
TEST INPUTS - Controls input display
status
Inactive
8.1
Appendix E
TEST TRANSMITTERS (TX’ERS)
8.2
Appendix E
DISPLAY HISTORY
8.3
Appendix E
MEMORY USAGE
8.4
Appendix E
SERVICE COUNTER
60,000
8.5
Appendix E
EVENT COUNTER
8.6
Appendix E
Menu 9 - Memory Tools
CLR CONTROL
9.1
Appendix F
CLR TRANSMITTERS (TX’ERS)
9.2
Appendix F
Menu 10 - Setup Travel
LIMIT TRAVEL
10.1
8.1
REPROFILE TRAVEL
10.2
9.5
SET PEDESTRIAN
10.3
14.1
This section illustrates how to locate, view and adjust
parameters.
Locating parameters
Refer to Appendix A for Consile Menu
Structure. Locate the required parameter and
note the MENU number. The example used in
(Fig. B.1)
displays “CLOSE LOCK TIME”
Changing Setting
a. Press NEXT/PREV to navigate to the required menu.
b. Press SET to show the sub-menu.
c. Press NEXT/PREV to go to the required sub-menu.
d. Press OPEN/CLOSE to change parameter setting.
Holding the button down causes the parameter’s
value to change rapidly. The longer the button is held
the faster the value changes.
e. Press SET to SAVE setting.
Reload Default Setting
a. Press NEXT/PREV buttons to display LOAD DEFAULT
screen.
b. Press SET to load the default value.
Return To Menu
If the parameter values are not to be changed, press
EXIT to return to sub menu. Press EXIT again to return
to the MAIN SCREEN.
2: Close Lock
Time (SEC) 0.5
2: Close Lock
Time (SEC) 0.5
Fig B.1
Fig B.2
B - Viewing and Editing Parameters
Parameter name
Parameter
value
Displays next
parameter
in list
Parameter number in list
Enter Edit
Mode
Displays previous
parameter in list
Returns back to menu
Enter Edit Mode
View Mode (No cursor)
Edit Mode (Cursor shown)
Increase
value
Displays “Load
Default?” screen,
giving option of
loading default value
Exits back to View Mode
with no changes made
Decrease
value
Saves new
value and exits
back to View
Mode
Displays “Load
Default?”
screen, giving
option of
loading default
value
Cursor shown
Parameter
Min
Max
Default
Step
Unit
Menu
Section
HOMING / SETUP SPEED VOLTS
Voltage applied to motors when setting up the travel limits
12
24
12
1
Volts
6.5
STOP PAUSE TIME
Pause time used between motor direction changes
0.0
2.0
0.3
0.1
SEC
6.6