18
NeoSlider
TM
- Sliding Gate Opener NES-24V3
Owner Installation Instructions
16. Accessories Installation
LIGHT REL
AY MODULE
POW
ER
SUPPL
Y
V+
0V
SAFETY B2
SAFETY B1
OV
OPEN
STOP
CLOSE
OSC
SWIPE
PEDESTRIAN
OV
V+
OUT2
V+
OUT1
Wiring Output1 And Output2
Outputs 1 and 2 are used to control a lock, Light or
Safety Beam power. Which output is to control which
function and the way it is controlled is programmable.
If using these outputs make sure that the functions are
configured for correct operation prior to setting the
travel limits. OUTPUT1 or OUTPUT2 is used to activate
an optional external relay module (RO-1) which in turn
is used to switch the load.
16.1 Fitting Solenoid Or Magnetic Locks
Install the lock mechanism on the gate as per the
manufacturers instructions. See
Fig. 16.1
for the wiring
diagram.
Menu 4. Lock Times
Lock output can be programmed for both hold and pulse
mode. The operation of the lock can be programmed
to activate prior to the gate and behave differently on
open cycles to that on close cycles.
a. Press NEXT or PREV on the wall control unit to navigate to
Menu 4 Lock Times.
b. Press SET to select the sub menu.
c. Press NEXT or PREV to navigate through the sub
menu.
d. Press OPEN to increase or CLOSE to decrease the
time.
e. Press SET to save the new time.
f. Press the EXIT button two times to exit and test the
locks operation.
Pulse Lock
LOCK REL
AY MODULE
POW
ER
SUPPL
Y
V+
0V
SAFETY B2
SAFETY B1
OV
OPEN
STOP
CLOSE
OSC
SWIPE
PEDESTRIAN
OV
V+
OUT2
V+
OUT1
Fig 16.1
Fig 16.2
16.2 Fitting Courtesy Lights
An AC or DC courtesy light can be activated via an
output on the gate opener control board. Connect the
light as per the diagram.
(Fig. 16.2)
WARNING: A qualified electrician must
perform the installation where 240V AC
power is used.
Menu 5. Light Times
a. Press NEXT or PREV on the wall control unit to
navigate to Menu 5 Light/Lock Times.
b. Press SET to select the sub menu.
c. Press NEXT or PREV to navigate through the sub
menu.
d. Press OPEN to increase or CLOSE to decrease the
time.
e. Press SET to save the new time.
f. Press the EXIT button two times to exit.