48
Technical Manual
NAM-CLEAR-MT-EN-A
The information contained in this document is the property of Automatic Systems
and is confidential. The recipient shall refrain from using it for any purpose other
than for the use of the products or the execution of the project to which it refers
and from communicating it to third parties without prior written agreement from
Automatic Systems. The document is subject to change without notice.
5.12. Single-presence detection adjustment (optional)
M1 to M8:
Transducer connectors
LD1 to LD8: LED signal of the corresponding transducer
J1:
Bar display connector
TR1 to TR8: Signal intensity of corresponding transducer
Clockwise rotation => signal intensity increase
TR10:
Signal compression
Clockwise rotation => compression reduction (i.e., increased security)
TR11: Sensitivity
Clockwise rotation => sensitivity increase
SW3, DIP2: ON => Buzzer activation when more than one person is detected in the booth
LD12:
LED lights up when more than one person is detected in the booth
PL1 + LD11: RESET LED signal
F1:
800-mA
fuse
ST1
1
12
M11
P13
M1
RL1
LD1
TR1
LD2
TR2
LD3
TR3
LD4
TR4
LD5
TR5
LD6
TR6
LD7
TR7
LD8
TR8
LD9
TR9
M2
M3
M4
M5
M6
M7
M8
M9
TR10
TR11
800
m
A
F1
LD11
LD10
LD12
BZ1
PL1
U3
SW3
ON
1
2
SW2
ON
1
2
SW1
J1
M10
1
VB 1290/9 E
JP2
LD13
Board
VB1290/9