4.8.1. Console description
LCD
Displays parameter values, booth status, alarms (see section 5.2).
SYSTEM
(key No. 1)
OFF
Shuts down power to the unit and all its components (main board VB3406
remains powered on). The booth is in power failure mode (see section 4.6).
ON
Turns on power to the unit:
WARNING
: The system undergoes an initialization phase that lasts
approximately 1 minute (SA obstacle opens and closes, then NSA obstacle
opens and closes); during this phase, the safety devices are not operational
and the booth cannot be used.
The version of the program encoded in the microprocessor of main board
VB3406 is displayed on screen.
When the initialization phase is completed, the booth is operational in
accordance with the set parameters.
Note
: The parameters used are those set when the console is powered off.
Parameter status is displayed on screen; the parameters can be changed
via the PROGRAM function of the SYSTEM key switch (see section 4.8.2).
DAYTIME
: Operating mode selected (AM / PM / NIGHT)
MODE
: Automatic or operator-controlled opening
DIREC
: Direction(s) of passage that are in use
M.D.
: Metal detector (optional) activated or deactivated
CONS
: Type of console activated (1 = master; 2 = slave; 3 =
slave)
USER(S) IN
: single-presence detection on entry side (NSA to SA) activated
or deactivated
USER(S) OUT
: single-presence detection on exit side (SA to NSA) activated
or deactivated
PROGRAM Program mode enables console parameter modification (see section 4.8.2).
EMERG
(key No. 2)
OFF
Normal operation of the booth.
ON
Opening command sent to an optional separate evacuation door (not
included).
ON B
Opening command sent simultaneously to the 2 obstacles for evacuation in
both directions of passage.
"
EXTernal (NSA) and INTernal (SA) doors OPened".
1*
INT
SA door opening.
2*
EXT
NSA door opening.
3*
RESET
Acknowledge alarm to continue the normal cycle.
Note
: When the system triggers a false alarm (e.g., false detection of a left
object), the acknowledgement procedure is different.
EMERG key switch to the ON B position
RESET
RELEASE
EXT OP INT OP
DAYTIME USER(S) OUT
MODE
M.D.
DIREC USER(S) IN
Prog. xxxxxxxx.xxx
PLEASE WAIT…