34
Technical Manual
NAM-CLEAR-MT-EN-A
The information contained in this document is the property of Automatic Systems
and is confidential. The recipient shall refrain from using it for any purpose other
than for the use of the products or the execution of the project to which it refers
and from communicating it to third parties without prior written agreement from
Automatic Systems. The document is subject to change without notice.
4.8.4. Obstacle initialization
Turn the SYSTEM key switch of the console to the PROGRAM position.
Press F3, then F4 and then 1 to access the SERVICE menu.
Press button 1 or 2 of the console to access the corresponding menu.
1 = READ PATH: Position sensor initialization
Press button 1 or 2 to initialize the corresponding obstacle (1 for the SA obstacle and 2 for the NSA
obstacle) and perform the following sequence:
Press and hold button 8 until the obstacle is completely closed (press it even if it is already closed).
Press button 3 to zero out the current values (00 will be displayed on screen instead of xx).
Press and hold button 4 until the obstacle is completely open.
Press button 7 to access the SAVE menu:
Press button 7 to save the new coordinates.
WARNING
: When new coordinates are saved, the system performs an opening/closing cycle during
which the safety sensors are not activated.
To exit the menu without saving the new coordinates, press button 3.
Follow the same procedure to initialize the other obstacle.
Turn the SYSTEM key switch to the ON position to exit the READ PATH menu.
SAVE DATA AND RECORD
THE PATH ?
3= Cancel 7= Save
READ INT PATH
xx
3= Reset 7= Save
4= Open 8= Close
DOOR SELECTION
1= INTERNAL DOOR
2= EXTERNAL DOOR
SERVICE MENU
1= READ PATH
2= MOTOR PARAMETERS