HISTORY EVENTS
Event Description
and
Solutions
DEFAULS LOADED
When Controller performed Full Initialization.
MAIN DOOR OPEN
When the Main Door was opened.
MAIN DOOR CLOSE
When the Main Door was closed.
POWER UP TIME
Time at which power was restored to machine.
POWER DOWN TIME
Time power was lost to machine.
PRC BD NO COMM
Center Price Display board lost RL communication. See PRC BD NO
COMM error in this section.
KPD BD NO COMM
Keypad Display (Message Center) lost RL communication. See KPD BD
NO COMM error in this section.
TRT BD NO COMM
Refrigeration/Turret Module lost RL communication. See TRT BD NO
COMM error in this section.
CDT BD NO COMM
Credit Module lost RL communication. See CDT BD NO COMM error in
this section.
COMM RESTORED
This Event is logged when a previously lost RL COMM was restored. This
will also be the time at which the machine self recovered from the Serial
Error.
BA CREDIT STUC
The Credit line on the Pulse Bill Acceptor went active and never returned
inactive. See B.A. Creditline Stuck in troubleshooting of this section.
BA STACKER FULL
The Bill Acceptor has reported that it stacker is full. Empty stacker and
cycle machine power.
BA BILL JAM
The Bill Acceptor reported a Bill Jam. Clear Bill Acceptor and cycle
machine power.
BA FAULT
General Bill Acceptor Fault. Refer to Bill Acceptor’s Manual for
troubleshooting.
CARD RDR NO COMM
The MDB Card Reader has Lost Communication. See CARD NO COMM
in troubleshooting of this section.
CARD RDR NDS SRVC
The card reader requires service. Refer to the Card Reader’s Owners
Manual for service instructions.
CARD RDR FAULT
General Card Reader Fault. Refer to the Card Reader’s Owners Manual
for service instructions.
ERRORS CLEARED
This event is logged when CLEAR ERRORS was saved to YES and
service mode was properly exited.
HEALTH ERR CLRD
This event is logged, along with an ERRORS CLEARED event, when a
Health Error is Properly cleared.
TRT LOST SYN
This event occurs when the Refrigeration/Turret Module does not report
the turret at the same position as the Main Controller. Probable cause is
temporary power loss to the Refrigeration/Turret Module. Check plugs and
harnessing.
TRT OVERRUN
The turret did not stop properly on the next turret position and over shoot
the 1/2 cycle switch. This is possible in a loaded turret if a Delivery Door is
opened as the turret is coming to the next position. Repeated logging of
this error might suggest attempted machine tampering or intermittent 1/2
cycle switch problems (see TRT NEVER LEFT error in this section). The
machine will recover from this by automatically finding the Zero Position, if
in operating mode. In service mode the TURN TILL ZERO prompt will
appear.
Summary of Contents for Showcase 748
Page 73: ...APi 748 V1 1 406 6 2 P N 77500001 Back Main Door Exterior ...
Page 75: ...APi 748 V1 1 406 6 4 P N 77500001 Back Message Center ...
Page 77: ...APi 748 V1 1 406 6 6 P N 77500001 Back Main Door Interior ...
Page 79: ...APi 748 V1 1 406 6 8 P N 77500001 Back Lower Main Door Components ...
Page 81: ...APi 748 V1 1 406 6 10 P N 77500001 Back Coin Mech Compartment ...
Page 83: ...APi 748 V1 1 406 6 12 P N 77500001 Back Door Assembly Coin Mech Compartment ...
Page 85: ...APi 748 V1 1 406 6 14 P N 77500001 Back Cabinet Final Assembly ...
Page 88: ...APi 748 V1 1 406 6 17 P N 77500001 Back This Page Intentionally Left Blank ...
Page 91: ...APi 748 V1 1 406 6 20 P N 77500001 Back Main Power Switch ...
Page 93: ...APi 748 V1 1 406 6 22 P N 77500001 Back Turret Drive Motor ...
Page 97: ...APi 748 V1 1 406 6 26 P N 77500001 Back Plate Assembly Locks Delivery Door ...
Page 99: ...APi 748 V1 1 406 6 28 P N 77500001 Back Refrigeration Unit 120 V Domestic Control Box Assem ...