APi 748 V1.1 406
3.13
P/N 77500001
Back
Pressing the [4] Key from “Service”
the display will prompt “History”
KEY [4]
History
– This menu contains the Machine
History Log, Error Log, and Temperature Logs.
The operator may view, clear, or print logs from
this menu. Each function in this service menu
requires a two-key entry to run; the first key is [4],
and the second key is one of the following:
[1] View the History log
[2] View the Error log
[3] View the Temperature log
[4] Not used
[5] Clear the History log
[6] Clear the Error log
[7] Clear the Temperature log
[8] Not used
[9] Print a selected log
[0] Not used
View History Log [4][1]
This feature allows the operator to view the last 50
events in the History Log.
DISPLAY:
“xx = logged event”
xx is the event number
logged event is the event
[1] Scrolls forward through History Log
[2] Scrolls backward through History Log
[3] Toggles between event and time/date of the
event
[RESET] Returns to the top of the service mode
History Log Detailed
When the log is displayed on the Message
Center, the most recent event recorded will be
displayed. If the log is full, the log entry number
will be 49; otherwise, the log entry number will be
the same as the number of entries in the log. As
more entries are recorded, the oldest entries are
discarded so only the most recent 50 remain in
the log.
When the History Log is displayed, it requires two
lines on the display. The first line shows the log
number and the event, and the second line shows
the time and date it was logged.
Example of history log entry displayed:
6 = POWER UP TIME
Push key [3] to display line 2:
6 = 8.05AM 1-05-01
Example history log printout: (see 4-9)
AUTOMATIC PRODUCTS
748 VER xx.xx
- - - - - - - - - - - - - - - - - - - - -
HISTORY LOG
11:46 FRI 01-05-2001
- - - - - - - - - - - - - - - - - - - - -
8:37AM 1-02-01 DEFAULTS LOADED
10:36AM 1-02-01 POWER DOWN TIME
10:41AM 1-02-01 POWER UP TIME
12:42PM 1-02-01 MAIN DOOR OPEN
12:45PM 1-02-01 MAIN DOOR CLOSE
4:23PM 1-04-01 POWER DOWN TIME
8:05AM 1-05-01 POWER UP TIME
Error Log [4][2]
This log contains a list of errors the machine has
detected. This log includes the last 20 errors.
DISPLAY:
“xx = logged error”
xx is the event number
[1] Scrolls forward through Error Log
[2] Scrolls backward through Error Log
[3] Toggles between error and time/date the error
occurred
[RESET] Returns to the top of the service mode
Error Log Detailed
When the log is displayed on the Message Center, the
most recent error recorded will be displayed. If the log
is full, the log entry number will be 19, otherwise the
log entry number will be the same as the number of
entries in the log. As more entries are recorded, the
oldest entries are discarded so only the most recent
20 remain in the log.
When the error log is displayed, it requires two lines
on the display. The first line shows the log number
and the error, and the second line shows the time and
date it was logged.
Example of error log entry displayed:
1 = HEALTH TIME OUT
Push key [3] to display line 2:
1 = 10.36AM 1-02-01
Example error log printout: (see 4-9 to print)
AUTOMATIC PRODUCTS
748 VER xx.xx
- - - - - - - - - - - - - - - - - - - - -
ERROR LOG
11:46 FRI 01-05-2001
- - - - - - - - - - - - - - - - - - - - -
8:37AM 1-02-01 MAIN DOOR OPEN
10:36AM 1-02-01 HEALTH TIME OUT
Summary of Contents for Showcase 748
Page 73: ...APi 748 V1 1 406 6 2 P N 77500001 Back Main Door Exterior ...
Page 75: ...APi 748 V1 1 406 6 4 P N 77500001 Back Message Center ...
Page 77: ...APi 748 V1 1 406 6 6 P N 77500001 Back Main Door Interior ...
Page 79: ...APi 748 V1 1 406 6 8 P N 77500001 Back Lower Main Door Components ...
Page 81: ...APi 748 V1 1 406 6 10 P N 77500001 Back Coin Mech Compartment ...
Page 83: ...APi 748 V1 1 406 6 12 P N 77500001 Back Door Assembly Coin Mech Compartment ...
Page 85: ...APi 748 V1 1 406 6 14 P N 77500001 Back Cabinet Final Assembly ...
Page 88: ...APi 748 V1 1 406 6 17 P N 77500001 Back This Page Intentionally Left Blank ...
Page 91: ...APi 748 V1 1 406 6 20 P N 77500001 Back Main Power Switch ...
Page 93: ...APi 748 V1 1 406 6 22 P N 77500001 Back Turret Drive Motor ...
Page 97: ...APi 748 V1 1 406 6 26 P N 77500001 Back Plate Assembly Locks Delivery Door ...
Page 99: ...APi 748 V1 1 406 6 28 P N 77500001 Back Refrigeration Unit 120 V Domestic Control Box Assem ...