10-6
CARE OF YOUR MOTORHOME
12V TROUBLESHOOTING CHART (continued)
230V TROUBLESHOOTING CHART
Symptom
Cause
Remedy
230V system inoperative
No site power
Check site supply
RCD/MCB switches tripped out
Reset circuit breakers
RCD/MCB keeps tripping
Fault on 230V supply
Check supply including polarity
out
Faulty appliance
Turn off all appliances, reset
circuit breakers, turn on
appliances until fault occurs.
Isolate faulty appliance
Overload on current
10A maximum available do not
consumption by appliance
use appliance
Water heater does not
No power
Switch on MCB isolator switch
operate on 230V
and check 6amp MCB is on
Water heater does not
Overtemperature trip activated
Reset thermal cut-out (refer to
operate on 230V
operating instructions)
Battery charger does not
Charger switched off
Switch on MCB isolator switch
operate
and check 6amp MCB is on
Refrigerator does not operate
Switch on refrigerator
Check position of thermostat
on 230V
thermostat dial not ‘on’
dial
Element fault
Refer to dealer
Cooker Hotplate
Not heating up
Make sure 230V is switched on.
at isolator
Check trip switch
Check 10amp MCB is on
Symptom
Cause
Remedy
Water Heater not
Fuse 3 blown
Find fault and replace fuse with
operating/cuts out
same rating
Low battery charge
Recharge battery
Unit fault
Refer to dealer
Cooker ignition not operating
Fuse 3 blown
Find fault and replace fuse with
same rating
Spark unit fault
Refer to dealer
Fault on cooker unit
Refer to dealer
Fridge gas ignition not
Fuse 3 blown
Find fault and replace fuse with
operating
same rating
Ignition control switch fault
Refer to dealer
Fridge ignition switch flashes
Fault on fridge unit
Refer to dealer
but gas does not ignite
Ignition can be heard to be
Faulty fridge ignition switch
Refer to dealer
sparking but no flashing on
fridge switch
Fridge does not operate on
Fuse 8 blown
Find fault and replace fuse with
12V when engine is running
same rating
Fault on fridge relay
Refer to dealer
Fault on fridge unit
Refer to dealer
Summary of Contents for warwick duo 2008
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 20: ...6 4 SAFETY SECURITY ...
Page 40: ...7 20 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 68: ...9 24 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Page 69: ...9 25 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Page 75: ...9 31 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT WARWICK DUO ...
Page 78: ...9 34 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY WARWICK DUO ...
Page 79: ...9 35 FITTED EQUIPMENT SINGLE BED ASSEMBLY WARWICK DUO ...
Page 80: ...9 36 FITTED EQUIPMENT DOUBLE BED ASSEMBLY WARWICK DUO ...
Page 84: ...9 40 FITTED EQUIPMENT ...
Page 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2008 Ref 21082 ...