9-8
FITTED EQUIPMENT
OPERATING INSTRUCTIONS
Caution:
Always observe the operating
instructions and “Important operating notes”
prior to starting. The vehicle owner is
responsible for the correct operation of the
appliance.
Note:
Before using for the first time, it is
essential to flush the entire water supply
through with clean warm water. If the heater
is not being used, always drain the water
contents if there is a risk of frost.
There can
be no claims under guarantee for damage
caused by frost!
Power selector switch
Note:
Switching on the electric heating
elements as well does not increase the
maximum heating power.
s = Room temperature sensor
The thermostat setting on the control panel (1-5) must
be determined individually depending on the heating
requirement and the type of vehicle. For an average
room temperature of about 23ºC, we recommend a
thermostat setting of about 4.
Control panel
Note:
The LEDs are visible only when the
unit is switched on.
Room thermostat
To measure the room temperature, an
external room temperature sensor is located
in the vehicle. The location of the sensor is
determined individually by the vehicle
manufactuer, depending on the vehicle type;
consult the operation instructions for your
vehicle for further details.
a = Power selection rotary switch
b = Electric operation 230V, 1800W.
c = Electric operation 230V, 900W.
d = Gas operation.
e= Mixed operation* (gas and electricity, 900W).
f = Mixed operation* (gas and electricity, 1800W).
g = Yellow LED on = Electrical operation
* Winter mode only. In summer mode the unit
automatically selects electric operation at the pre-
selected electrical power of 900W or 1800W.
h = Rotary switch for room temperature (1-5)
k = green LED lit “Operation”
green LED blinking
“after-running” is active in order to reduce the unit’s
temperature
l = Summer operation (water temperature 40ºC or 60ºC)
m = Winter operation (heating without water temperature
monitoring or with drained water system)
n = Winter operation (heating with water temperature
monitoring)
o = Rotary “Off” switch
p = Yellow LED lit “Boiler heat-up phase”
r = Red LED lit, red LED blinking “Failure”
Summary of Contents for warwick duo 2008
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 20: ...6 4 SAFETY SECURITY ...
Page 40: ...7 20 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 68: ...9 24 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Page 69: ...9 25 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Page 75: ...9 31 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT WARWICK DUO ...
Page 78: ...9 34 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY WARWICK DUO ...
Page 79: ...9 35 FITTED EQUIPMENT SINGLE BED ASSEMBLY WARWICK DUO ...
Page 80: ...9 36 FITTED EQUIPMENT DOUBLE BED ASSEMBLY WARWICK DUO ...
Page 84: ...9 40 FITTED EQUIPMENT ...
Page 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2008 Ref 21082 ...