7-14
CONNECTION OF SERVICES
The Residual Current Device (RCD) is
basically provided to protect the user from
lethal electric shock. The RCD will turn off
(trip) if the current flowing in the live
conductor does not fully return down the
neutral conductor, i.e. some current is
passing through a person down to earth or
through a faulty appliance.
To ensure the RCD is working correctly, the
test button should be operated each time the
vehicle is connected to the mains supply (see
page 7-20).
The Miniature Circuit Breakers (MCB’s)
operate in a similar way to traditional fuses
and are provided to protect the wiring
installation from overload or short circuit. If an
overload occurs the MCB will switch off the
supply. If this occurs you should investigate
the cause of the fault before switching the
MCB back on.
The following table shows the rating and
circuit allocation for the three MCB’s.
MCB
Rating
1
10 Amps
2
10 Amps
3
6 Amps
Fuses
WARNING
When replacing fuses always replace a
fuse with the correct value. NEVER
replace with a higher value/rating as this
could damage the wiring harness. If a
replacement fuse ‘blows’ do not keep
replacing the fuse as you could damage
the wiring harness. Please investigate the
fault and contact your dealer.
The following table shows the fuse allocation
for the 12 fuses fitted to the EC155 PSU.
FUSE/MCB TABLE
Fuse
Rating
1
15 Amps
2
10 Amps
3
5 Amps
4
10 Amps
5
10 Amps
6
10 Amps
7
10 Amps
8
5 Amps
9
20 Amps
10
20 Amps
11
10 Amps
12
15 Amps
Battery
20 Amps
Summary of Contents for warwick duo 2008
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 20: ...6 4 SAFETY SECURITY ...
Page 40: ...7 20 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 68: ...9 24 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Page 69: ...9 25 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Page 75: ...9 31 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT WARWICK DUO ...
Page 78: ...9 34 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY WARWICK DUO ...
Page 79: ...9 35 FITTED EQUIPMENT SINGLE BED ASSEMBLY WARWICK DUO ...
Page 80: ...9 36 FITTED EQUIPMENT DOUBLE BED ASSEMBLY WARWICK DUO ...
Page 84: ...9 40 FITTED EQUIPMENT ...
Page 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2008 Ref 21082 ...