10-7
CARE OF YOUR MOTORHOME
LPG TROUBLESHOOTING CHART
Symptom
Cause
Remedy
Appliance will not light
No gas
Change the cylinder
Check cylinder is turned on
Check isolation valve is open
Low battery (auto ignition)
Charge battery
Appliance lights but goes out
Flame supervision device (FSD) Refer to dealer
immediately the FSD override
is not functioning correctly
is released
Odour
Gas leak
Turn off the gas at the cylinder
and do not use the gas system
until the problem has been
rectified
In the event of a leaking cylinder,
if possible, position the cylinder
in an open area away from any
sources of ignition. Contact the
site warden and/or the local gas
supplier
Yellow flame
Lack of primary air. please note
Refer to dealer
yellow tipping to the flame is
normal
Orange flame
Particles of dust or dirt in the
Reduce the amount of dust in
mixing tube being carried
air
through the burner ports
Burner ports partically blocked
Refer to dealer
Floating flame
Lack of secondary air
Check all vents are clear (air
inlet to vehicle)
Blocked retention ports
Check retention ports are clear
If in an oven
Check the flue way is clear
Summary of Contents for Peugeot Kemerton
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 24: ...6 8 SAFETY SECURITY ...
Page 42: ...7 18 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 69: ...9 23 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Page 70: ...9 24 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Page 75: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT ...
Page 79: ...9 33 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY ...
Page 80: ...9 34 FITTED EQUIPMENT DOUBLE BED ASSEMBLY ...
Page 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2011 Ref 21210 ...