12-6
SERVICE DETAILS
obstructed.
Check delivery hose and electric cable are
secure and satisfactory.
System Check
Operate pump. Check all piping for leaks.
Operate taps and shower. If a hot water
system is fitted, it can be checked for leaks
etc., using cold water. (Note: Aerated water
from tap could be due to a leak on the
suction side of the pump).
Waste Water System
With water running through the drain pipes,
check for leaks and satisfactory draining of
water from sinks etc.
Couplings and Fluids
Check that the appropriate markings are
used - blue for fresh water, grey for waste
water. Ensure a sealing off cover is supplied
for each coupling.
Check that filler positions are designated
“petrol”, “diesel” or “water” as appropriate.
Toilet Waste Tank
Check that any fixed tank intended to receive
discharge from a toilet is fitted with either a
level or full indicator.
SECTION 10 - ELECTRICAL
SYSTEMS
Extra Low Voltage 12 Volts (excluding
vehicle)
Battery/ies:
•
Check battery/ies for condition.
•
Check connections, wires, fuses and
relays appertaining to the habitation
electrics.
Wiring:
•
Examine all visible wiring.
•
Check all connections and joints are
sound and satisfactory.
Fuses/Fuse Holders:
•
Ensure that fuses and fuse holders used
to protect the habitation electrics are
satisfactory and that fuse ratings are
compatible with the circuit appliances
being protected.
Appliances:
•
Inspect all appliances for damage, signs
of overheating and secure fixing.
Function test all appliances.
Mains 230 Volt System
It is recommended that the inspection and
certification of the 230 volt system be carried
out by a qualified electrician who is an
approved contractor of the NICEIC (National
Inspection Council for Electrical Installation
Contracting) or a member of the Electrical
Contractors Assocation.
SECTION 11- VENTILATION
High Level
Check all high level ventilators, including roof
lights, are free from obstruction and allow a
free flow of air.
Low Level
Check all low level ventilators are free from
obstructions and allow a free flow of air. If the
ventilator is manually adjustable then ensure
the mechanism is free and operating
correctly.
Summary of Contents for Peugeot Kemerton
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 24: ...6 8 SAFETY SECURITY ...
Page 42: ...7 18 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 69: ...9 23 FITTED EQUIPMENT 1 2 4 3 5 6 ...
Page 70: ...9 24 FITTED EQUIPMENT 7 8 10 9 11 12 ...
Page 75: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT ...
Page 79: ...9 33 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY ...
Page 80: ...9 34 FITTED EQUIPMENT DOUBLE BED ASSEMBLY ...
Page 106: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 549278 MY 2011 Ref 21210 ...