9-15
FITTED EQUIPMENT
Draining the water heater
Switch off power to water pump (main or
pump switch).
Open hot water taps in kitchen and
bathroom.
In order to check the water that is flowing out,
place an appropriate container (capacity 10
litres) beneath the drain valve (FrostControl)
drainage muff (x).
Turn the rotary switch on the drain valve by
180º until it engages, whereby the push
button moves out and the drain valve opens.
Check whether all of the water in the boiler
(10 litres) has been drained into the container
via the drain valve.
There shall be no claims under guarantee for
damage caused by frost!
Maintenance
Only original Truma parts may be used for
maintenance and repair work!
The materials in the device that come into
contact with water are drinking water safe.
Bio-film, deposits and limescale must be
removed using chemicals to protect the unit
from infestation by micro-organisms. Only
Chloride-free products must be used in order
to prevent damage to the unit.
The effectiveness of the use of chemicals to
combat micro-organisms in the unit can be
increased by heating the water in the boiler to
70ºC at regular intervals.
To do this, on the control panel, select Gas
Operation, then select Summer Operation
60ºC.
Note:
Once the water in the boiler has
reached a temperature of 60ºC, the burner
will switch off. The unit must stay switched on
for at least 30 minutes and no warm water
may be removed. The residual heat in the
heat exchanger will heat the water up to
70ºC.
Fuses 12V
The fuse is in the electronics beneath the
connection cover. Replace the unit’s fuse
only with an identical fuse.
Device fuse: 10A - slow - (T 10A).
Fuses 230V
CAUTION:
The fuse and the power supply
lines must only be replaced by an expert!
WARNING: The unit must be
disconnected from the mains (all poles)
before opening the electronic housing
lid.
The fuse in the power electronics (16)
beneath the electronic housing lid.
This fine fuse must always be replaced with
a fuse of the same type: 10A, slow,
interrupting capacity “H”.
Summary of Contents for Broadway FB
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 24: ...6 8 SAFETY SECURITY ...
Page 59: ...7 35 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 60: ...7 36 CONNECTION OF SERVICES ...
Page 93: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT BROADWAY EL DUO ...
Page 94: ...9 30 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT BROADWAY FB ...
Page 99: ...9 35 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY BROADWAY EL DUO ...
Page 100: ...9 36 FITTED EQUIPMENT SINGLE BED ASSEMBLY BROADWAY EL DUO ...
Page 101: ...9 37 FITTED EQUIPMENT DOUBLE BED ASSEMBLY BROADWAY EL DUO ...
Page 103: ...9 39 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY BROADWAY FB ...
Page 104: ...9 40 FITTED EQUIPMENT DOUBLE BED ASSEMBLY BROADWAY FB ...
Page 108: ......
Page 128: ...12 10 SERVICE DETAILS ...
Page 130: ...13 2 NOTES Designed and Printed by Preset Graphics HB1103 MY 2013 Ref 21301 ...