10-5
CARE OF YOUR MOTORHOME
TROUBLESHOOTING
The following are a series of fault finding charts to which you should refer in the event of
problems you may have regarding 230/12V, LPG and water. This should be used as a guide only,
and in the case of an electrical fault, where a fuse has blown or an MCB tripped out, the fault
must be located before replacing the fuse. If a fault is suspected with the LPG system, consult a
GAS SAFE registered technician.
If in doubt consult a qualified technician or your local Auto-Sleeper dealer.
12V TROUBLESHOOTING CHART
Symptom
Cause
Remedy
Habitation 12V does not
Main 20A fuse blown
Check/Replace
operate
Battery Discharged
Recharge
Switch on control panel in off
Switch to on
position
Vehicle ignition ‘on’
Switch ‘off’ ignition
Habitation battery not
Main 20A fuse blown
Check/Replace
charging
Relay fault
Refer to dealer
Contacts dirty/loose on
Clean and check for tightness
battery terminals
Poor earthing
Check earthing to chassis point
Battery does not hold its
Failed battery
Check cells with hydrometer
charge
change electrolyte if necessary
Current being drawn
Check all appliances are off
when not in use
Battery discharges over a
Poor battery cell condition
Check cells with hydrometer
short time with appliances
Failed battery
Change battery
operating
Battery not fully charged
Fully recharge battery
No power to one or more
Circuit fuse blown
Find fault and replace fuse with
12V appliances
same rating
Lights dull/only one tube
Low battery charge
Check battery
illuminating
Faulty light unit/tube
Replace/Check
Water pump not operating
Switch on panel ‘off’
Switch it ‘on’
Pressure switch on pump not
Refer to dealer
operating
Fuse 4 blown
Find fault and replace fuse with
same rating
No power on 12V socket
Fuse 9 blown
Find fault and replace fuse with
outlet
same rating
12V plug incorrectly
Check plug
connected/wired
Summary of Contents for Broadway FB
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 24: ...6 8 SAFETY SECURITY ...
Page 59: ...7 35 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 60: ...7 36 CONNECTION OF SERVICES ...
Page 93: ...9 29 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT BROADWAY EL DUO ...
Page 94: ...9 30 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT BROADWAY FB ...
Page 99: ...9 35 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY BROADWAY EL DUO ...
Page 100: ...9 36 FITTED EQUIPMENT SINGLE BED ASSEMBLY BROADWAY EL DUO ...
Page 101: ...9 37 FITTED EQUIPMENT DOUBLE BED ASSEMBLY BROADWAY EL DUO ...
Page 103: ...9 39 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY BROADWAY FB ...
Page 104: ...9 40 FITTED EQUIPMENT DOUBLE BED ASSEMBLY BROADWAY FB ...
Page 108: ......
Page 128: ...12 10 SERVICE DETAILS ...
Page 130: ...13 2 NOTES Designed and Printed by Preset Graphics HB1103 MY 2013 Ref 21301 ...