7-37
CONNECTION OF SERVICES
3.14
Common Fault Table
(continued)
Fault
Possible Cause
Proposed Fix
No 12 volt output
Power button on control
Turn power on at control panel
from PSU
panel not switched to on
(continued)
Battery flat / Battery fuse
Recharge battery, check fuses, check charging voltage is present at
battery
Fuse blown
Check all fuses are intact and the correct value fuse is installed as
per fuse table
Equipment switched off /
Check equipment is switched on and connected to the 12V supply
unplugged
PSU overheated / auto
Reduce load on system. Allow PSU to cool down. PSU will
shutdown operated
automatically restart when cool
Other fault
Contact your Dealer
Pump not
Fuse blown
Replace fuse with correct value as per fuse table
working
Pump turned off
Turn pump on by pressing the pump button at the control panel
Setting incorrect
Both the internal and external pump feeds are controlledd from the
control panel. To alter the setting of the pump switch see your dealer.
Ensure the setting matches your desired requirement.
3.15
Contact details
Sargent Electrical Services Limited, provide a technical help line during office hours. Please
contact 01482 678981 if you require technical help. For out of hour support please refer to the
tech support section of the Sargent web site
www.sargentltd.co.uk
4
EC480 Control Panel
In addition to the information contained in section 2.5 (Control Panel Operation), the following
section provides further detail information.
4.1
Backlight Operation
The screen backlight (illumination) is turned on and off automatically. When operating on battery
power only the backlight time is 30 seconds. When operating on mains power the backlight time
is increased to 2 minutes. Pressing the select button will reactivate the backlight.
If the large clock screen is selected (see 4.4.4 below) and the mains supply is on then the
backlight will remain on continuously.
4.2
Header Area
The header area of the screen shows the following information;
At the left, the external temperature in centigrade
At the right, the internal temperature in centigrade
In the centre, the current time (24 hour clock)
In addition to the above, the following symbols (when shown) indicate;
Mains supply connected and charger switched on
Alarm clock set
Event timer set
Summary of Contents for lancashire ek
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 70: ...7 46 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 104: ...9 30 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT LANCASHIRE EK ES ...
Page 105: ...9 31 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT LANCASHIRE EL ...
Page 110: ...9 36 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE EK ...
Page 111: ...9 37 FITTED EQUIPMENT SINGLE BED ASSEMBLY LANCASHIRE EK ...
Page 112: ...9 38 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE EK ...
Page 113: ...9 39 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE ES ...
Page 114: ...9 40 FITTED EQUIPMENT BENCH SEAT SETTEE ASSEMBLY LANCASHIRE ES ...
Page 115: ...9 41 FITTED EQUIPMENT SINGLE BED ASSEMBLY LANCASHIRE ES ...
Page 116: ...9 42 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE ES ...
Page 117: ...9 43 FITTED EQUIPMENT OVERCAB BED LANCASHIRE ES ...
Page 118: ...9 44 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE EL ...
Page 119: ...9 45 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE EL ...
Page 132: ...11 2 USEFUL INFORMATION Superior craftsmanship within your reach at a dealer near you ...
Page 142: ...12 10 SERVICE DETAILS ...
Page 144: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 205136 HB1096 MY 2011 Ref 21234 ...